4.4 Article

Differences in Automated External Defibrillator Types in Out-of-Hospital Cardiac Arrest Treated by Police First Responders

出版社

MDPI
DOI: 10.3390/jcdd10050196

关键词

automated external defibrillator; out-of-hospital cardiac arrest; basic life support; police; first responder

向作者/读者索取更多资源

This retrospective observational study found that different AED models used by police first responders have varying time durations, but they do not significantly impact clinical patient outcomes. However, these time differences may be significant for training of first responders and development of improved AED designs.
Background: Police first responder systems also including automated external defibrillation (AED) has in the past shown considerable impact on favourable outcomes after out-of-hospital cardiac arrest (OHCA). While short hands-off times in chest compressions are known to be beneficial, various AED models use different algorithms, inducing longer or shorter durations of crucial timeframes along basic life support (BLS). Yet, data on details of these differences, and also of their potential impact on clinical outcomes are scarce. Methods: For this retrospective observational study, patients with OHCA of presumed cardiac origin and initially shockable rhythm treated by police first responders in Vienna, Austria, between 01/2013 and 12/2021 were included. Data from the Viennese Cardiac Arrest Registry and AED files were extracted, and exact timeframes were analyzed. Results: There were no significant differences in the 350 eligible cases in demographics, return of spontaneous circulation, 30-day survival, or favourable neurological outcome between the used AED types. However, the Philips HS1 and -FrX AEDs showed immediate rhythm analysis after electrode placement (0 [0-1] s) and almost no shock loading time (0 [0-1] s), as opposed to the LP CR Plus (3 [0-4] and 6 [6-6] s, respectively) and LP 1000 (3 [2-10] and 6 [5-7] s, respectively). On the other hand, the HS1 and -FrX had longer analysis times of 12 [12-16] and 12 [11-18] s than the LP CR Plus (5 [5-6] s) and LP 1000 (6 [5-8] s). The duration from when the AED was turned on until the first defibrillation were 45 [28-61] s (Philips FrX), 59 [28-81] s (LP 1000), 59 [50-97] s (HS1), and 69 [55-85] s (LP CR Plus). Conclusion: In a retrospective analysis of OHCA-cases treated by police first responders, we could not find significant differences in clinical patient outcomes concerning the respective used AED model. However, various differences in time durations (e.g., electrode placement to rhythm analysis, analysis duration, or AED turned on until first defibrillation) along the BLS algorithm were seen. This opens up the question of AED-adaptations and tailored training methods for professional first responders.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据