4.5 Article

Calibrating and Validating the MFI-UF Method to Measure Particulate Fouling in Reverse Osmosis

期刊

MEMBRANES
卷 13, 期 5, 页码 -

出版社

MDPI
DOI: 10.3390/membranes13050535

关键词

reverse osmosis; particulate fouling; MFI-UF; calibration; linearity

向作者/读者索取更多资源

This study aimed to calibrate and validate the MFI-UF method to ensure accurate measurements of particulate fouling in RO. The calibration of MFI-UF using standard particles showed strong linearity for dextran solutions but lack of reproducibility. For polystyrene solutions, MFI-UF linearity was verified at higher ranges but underestimated at lower ranges. Validation of MFI-UF using natural water demonstrated strong linearity over the entire measured range. Further research is needed to calibrate MFI-UF using heterogeneous mixtures of standard particles.
This study aimed to calibrate and validate the MFI-UF method in order to ensure the accuracy of particulate fouling measurements in RO. Firstly, the MFI-UF calibration was examined using two solutions of standard particles (dextran and polystyrene). Two main criteria were investigated: (i) MFI-UF linearity with particle concentrations at both low and high ranges of fouling potential and (ii) the reproducibility of MFI-UF linearity. Dextran solutions showed a strong MFI-UF linearity over the entire range of measured MFI-UF. However, the linearity was not reproducible, and different batches of dextran prepared under the same conditions produced very variable results. For polystyrene solutions, the MFI-UF linearity was verified at the higher range of MFI-UF (>10,000 s/L-2), while the MFI-UF at the lower range (<5000 s/L-2) appeared to be underestimated. Secondly, MFI-UF linearity was investigated using natural (surface) water under a wide range of testing conditions (at 20-200 L/m(2) center dot h using 5-100 kDa membranes). Strong MFI-UF linearity was obtained over the entire range of measured MFI-UF (up to 70,000 s/L-2). Thus, the MFI-UF method was validated to measure different levels of particulate fouling in RO. However, future research focusing on MFI-UF calibration is still required through the selection, preparation, and testing of heterogeneous mixtures of standard particles.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据