4.7 Article

Numerical investigation on the performance of a solar air heater using inclined impinging jets on absorber plate with parallel and crossing orientation of nozzles

期刊

出版社

ELSEVIER
DOI: 10.1016/j.csite.2023.102913

关键词

Jet solar air heater; Thermal performance; Nozzle orientation; Inclined jets

向作者/读者索取更多资源

This study investigates the performance enhancement of a solar air heater using inclined impinging jets on the heater surface. Two main sets of arrangements are considered for the jet nozzles including the parallel and crossing orientation of nozzles in consecutive rows. It was found that the proposed jet solar air heater improved the Nu number and thermohydraulic performance parameter compared to the conventional unimproved solar air heater.
This work investigates the performance enhancement of a solar air heater using inclined impinging jets on the heater surface. Two main sets of arrangements are considered for the jet nozzles including the parallel and crossing orientation of nozzles in consecutive rows. The RNG k -epsilon model is employed to simulate the turbulent flow in the channel. The influence of different geometrical and operational parameters such as jet diameter ratio (Dj /Dh), inclination angle (alpha, beta), stream wise pitch ratio (L /Dh), span wise pitch ratio (S /Dh), Re number and velocity ratio (Vr) on the hydraulic and thermal behavior of jet solar air heater was studied. Results showed that the proposed jet solar air heater improved the Nu number and thermohydraulic performance parameter compared to the conventional unimproved solar air heater. For the studied range of parameters, up to 4.26 times higher Nu number was obtained using the jet impingement compared to the smooth duct solar air heater. Moreover, it was shown that the amount of velocity ratio (Vr) is a significant factor when comparing the parallel and crossing orientations. Addi-tionally, results indicated that the increment of stream wise and span wise pitch led to the increment of the Nu number while having a minor effect on the friction factor. For example, the increment of L/dh from 0.3 to 0.6 leads to the reduction of f/fs of case 1 and case 4 by 6.5% and 1.09%, respectively Also, the increment of the jet diameter first raises the thermohydraulic performance parameter, and then with a further increment of diameter, the amount of thermo-hydraulic performance parameter decreases.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据