4.7 Article

Robotic-Arm-Based Force Control in Neurosurgical Practice

期刊

MATHEMATICS
卷 11, 期 4, 页码 -

出版社

MDPI
DOI: 10.3390/math11040828

关键词

neurosurgical robotics; optimal control; optimal speed shape

向作者/读者索取更多资源

This research proposes an optimal robotic arm speed shape in neurological surgery to minimise a cost functional that uses an adaptive scheme to determine the brain tissue force. Until now, there have been no studies or theories on the shape of the robotic arm speed in such a context. The authors have applied a robotic arm with optimal speed control in neurological surgery. The results of this research are as follows: In this article, the authors propose a control scheme that minimises a cost functional which depends on the position error, trajectory speed and brain tissue force. This work allowed us to achieve an optimal speed shape or trajectory to reduce brain retraction damage during surgery. The authors have reached two main conclusions. The first is that optimal control techniques are very well suited for robotic control of neurological surgery. The second conclusion is that several studies on functional cost parameters are needed to achieve the best trajectory speed of the robotic arm. These studies could attempt to optimise the functional cost parameters and provide a mechanical characterisation of brain tissue based on real data.
This research proposes an optimal robotic arm speed shape in neurological surgery to minimise a cost functional that uses an adaptive scheme to determine the brain tissue force. Until now, there have been no studies or theories on the shape of the robotic arm speed in such a context. The authors have applied a robotic arm with optimal speed control in neurological surgery. The results of this research are as follows: In this article, the authors propose a control scheme that minimises a cost functional which depends on the position error, trajectory speed and brain tissue force. This work allowed us to achieve an optimal speed shape or trajectory to reduce brain retraction damage during surgery. The authors have reached two main conclusions. The first is that optimal control techniques are very well suited for robotic control of neurological surgery. The second conclusion is that several studies on functional cost parameters are needed to achieve the best trajectory speed of the robotic arm. These studies could attempt to optimise the functional cost parameters and provide a mechanical characterisation of brain tissue based on real data.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据