4.7 Article

Multi-Target Detection of Nuts and Peanuts as Hidden Allergens in Bakery Products through Bottom-Up Proteomics and High-Resolution Mass Spectrometry

期刊

FOODS
卷 12, 期 4, 页码 -

出版社

MDPI
DOI: 10.3390/foods12040726

关键词

tree nut allergy; peanut allergy; hidden allergens; LC-MS; MS analysis; peptide markers; bakery products

向作者/读者索取更多资源

Due to the increasing global incidence of allergy to nuts and peanuts, this paper describes the development of a multi-target method based on LC-MS, MS/MS to detect traces of five nuts species and peanuts in a bakery product. The method utilizes the LC-MS responses of selected peptides resulting from digestion of allergenic proteins, allowing for quantification down to mg·kg(-1) levels in the model cookie. This opens up interesting possibilities for quantifying hidden nuts/peanuts in bakery products and improving precautionary labelling.
Due to the growing global incidence of allergy to nuts and peanuts, the need for better protection of consumers sensitive to those products is constantly increasing. The best strategy to defend them against adverse immunological reactions still remains the total removal of those products from their diet. However, nuts and peanuts traces can also be hidden in other food products, especially processed ones, such as bakery products, because of cross-contamination occurring during production. Precautionary labelling is often adopted by producers to warn allergic consumers, usually without any evaluation of the actual risk, which would require a careful quantification of nuts/peanuts traces. In this paper, the development of a multi-target method based on liquid chromatography-tandem high resolution mass spectrometry (LC-MS, MS/MS), able to detect traces of five nuts species (almonds, hazelnuts, walnuts, cashews and pistachios) and of peanuts in an in-house incurred bakery product (cookie) through a single analysis is described. Specifically, allergenic proteins of the six ingredients were used as the analytical targets, and the LC-MS responses of selected peptides resulting from their tryptic digestion, after extraction from the bakery product matrix, were exploited for quantification, following a bottom-up approach typical of proteomics. As a result, nuts/peanuts could be detected/quantified down to mg center dot kg(-1) levels in the model cookie, thus opening interesting perspectives for the quantification of hidden nuts/peanuts in bakery products and, consequently, for a more rational use of precautionary labelling.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据