4.6 Article

Emergency load shedding strategy for high renewable energy penetrated power systems based on deep reinforcement learning

期刊

ENERGY REPORTS
卷 9, 期 -, 页码 434-443

出版社

ELSEVIER
DOI: 10.1016/j.egyr.2023.03.027

关键词

Emergency load shedding; Mismatch scenario; Deep reinforcement learning; Design of decision space

向作者/读者索取更多资源

This paper proposes an emergency load shedding method based on data-driven strategies and deep reinforcement learning. The traditional event-driven load shedding strategy faces the risk of mismatching in high renewable energy penetrated power systems. In order to address this challenge, the proposed method transforms the emergency load shedding strategy into a Markov Decision Process and optimizes it using deep reinforcement learning.
Traditional event-driven emergency load shedding determines the quantitative strategy by simulation of a specific set of expected faults, which requires high model accuracy and operation mode matching. However, due to the model complexity of renewable power generators and fluctuating power generation, traditional event-driven load shedding strategy faces the risk of mismatching in high renewable energy penetrated power systems. To address these challenges, this paper proposes an emergency load shedding method based on data-driven strategies and deep reinforcement learning (RL). Firstly, the reason for the possible mismatch of the event-driven load shedding strategy in the renewable power system is analyzed, and a typical mismatch scenario is constructed. Then, the emergency load shedding strategy is transformed into a Markov Decision Process (MDP), and the decision process's action space, state space, and reward function are designed. On this basis, an emergency control strategy platform based on the Gym framework is established for application of deep reinforcement learning in the power system emergency control strategy. In order to enhance the adaptability and efficiency of the RL intelligence agent to multi-fault scenarios, the Proximal Policy Optimization (PPO) is adopted to optimize the constructed MDP. Finally, the proposed reinforcement learning-based emergency load shedding strategy is trained and verified through a modified IEEE 39-bus system. The results show that the proposed strategy can effectively make correct strategies to restore system frequency in the event-driven load shedding mismatch scenario, and have good adaptability for different faults and operation scenarios. (c) 2023 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据