4.6 Article

Methicillin-Susceptible Staphylococcus aureus Biofilm Formation on Vascular Grafts: an In Vitro Study

期刊

MICROBIOLOGY SPECTRUM
卷 11, 期 2, 页码 -

出版社

AMER SOC MICROBIOLOGY
DOI: 10.1128/spectrum.03931-22

关键词

vascular graft; infection; biofilm; Staphylococcus aureus; in vitro; prosthesis infections

向作者/读者索取更多资源

The aim of this study was to quantify in vitro biofilm formation by methicillin-susceptible Staphylococcus aureus (MSSA) on the surfaces of different types of commonly used vascular grafts. The Dacron silver-triclosan and Omniflow II vascular grafts showed the greatest resistance to in vitro methicillin-susceptible Staphylococcus aureus biofilm formation compared to other vascular grafts.
The aim of this study was to quantify in vitro biofilm formation by methicillin-susceptible Staphylococcus aureus (MSSA) on the surfaces of different types of commonly used vascular grafts. We performed an in vitro study with two clinical strains of MSSA (MSSA2 and MSSA6) and nine vascular grafts: Dacron (Hemagard), Dacron-heparin (Intergard heparin), Dacron-silver (Intergard Silver), Dacron-silver-triclosan (Intergard Synergy), Dacron-gelatin (Gelsoft Plus), Dacron plus polytetrafluoroethylene (Fusion), polytetrafluoroethylene (Propaten; Gore), Omniflow II, and bovine pericardium (XenoSure). Biofilm formation was induced in two phases: an initial 90-minute adherence phase and a 24-hour growth phase. Quantitative cultures were performed, and the results were expressed as log(10) CFU per milliliter. The Dacron-silver-triclosan graft and Omniflow II were associated with the least biofilm formation by both MSSA2 and MSSA6. MSSA2 did not form a biofilm on the Dacron-silver-triclosan graft (0 CFU/mL), and the mean count on the Omniflow II graft was 3.89 CFU/mL (standard deviation [SD] 2.10). The mean count for the other grafts was 7.01 CFU/mL (SD 0.82). MSSA6 formed a biofilm on both grafts, with 2.42 CFU/mL (SD 2.44) on the Dacron-silver-triclosan graft and 3.62 CFU/mL (SD 2.21) on the Omniflow II. The mean biofilm growth on the remaining grafts was 7.33 CFU/mL (SD 0.28). The differences in biofilm formation on the Dacron-silver-triclosan and Omniflow II grafts compared to the other tested grafts were statistically significant. Our findings suggest that of the vascular grafts we studied, the Dacron-silver-triclosan and Omniflow II grafts might prevent biofilm formation by MSSA. Although further studies are needed, these grafts seem to be good candidates for clinical use in vascular surgeries at high risk of infections due to this microorganism.IMPORTANCE The Dacron silver-triclosan and Omniflow II vascular grafts showed the greatest resistance to in vitro methicillin-susceptible Staphylococcus aureus biofilm formation compared to other vascular grafts. These findings could allow us to choose the most resistant to infection prosthetic graft. The Dacron silver-triclosan and Omniflow II vascular grafts showed the greatest resistance to in vitro methicillin-susceptible Staphylococcus aureus biofilm formation compared to other vascular grafts.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据