4.7 Article

Fluid-solid coupling model and biological features of large vestibular aqueduct syndrome

出版社

FRONTIERS MEDIA SA
DOI: 10.3389/fbioe.2023.1106371

关键词

large vestibular aqueduct syndrome (LVAS); vestibular aqueduct (VA); biomechanics; fluid solid coupling; sensorineural deafness

向作者/读者索取更多资源

This study established 3D numerical models of the inner ear of LVAS patients using CT images of the temporal bone. The fluid-solid coupling models were constructed to analyze the physiological features and pathophysiology of LVAS from a biomechanical perspective. The results showed that the deformation of the round window membranes increased with the increase in load. The fluid-solid coupling analysis also revealed that fluctuating cerebrospinal fluid pressure could affect inner ear pressure, and the size of the vestibular aqueduct had a limiting effect on the pressure.
Objective: Computed tomography (CT) images of the temporal bone of large vestibular aqueduct syndrome (LVAS) patients were used to establish 3D numerical models based on the structure of the inner ear, which are, in turn, used to construct inner ear fluid-solid coupling models. The physiological features and pathophysiology of LVAS were analyzed from a biomechanical perspective using finite element analysis. Methods: CT images of the temporal bone were collected from five children attending the Second Hospital of Dalian Medical University in 2022. The CT images were used to build 3D models of the inner ear containing the vestibular aqueduct (VA) by Mimics and Geomagic software, and round window membrane models and fluid-solid coupling models were built by ANSYS software to perform fluid-solid coupling analysis. Results: By applying different pressure loads, the deformation of the round window membranes occurred, and their trend was basically the same as that of the load. The deformation and stress of the round window membranes increased with the increase in load. Under the same load, the deformation and stress of the round window membranes increased with the expansion of the midpoint width of the VA. Conclusion: CT images of the temporal bone used clinically could establish a complete 3D numerical model of the inner ear containing VA. Fluctuations in cerebrospinal fluid pressure could affect inner ear pressure, and VA had a limiting effect on the pressure from cerebrospinal fluid. The larger the VA, the smaller the limiting effect on the pressure.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据