4.6 Article

Experimental Validation of a Bidirectional Multilevel dc-dc Power Converter for Electric Vehicle Battery Charging Operating under Normal and Fault Conditions

期刊

ELECTRONICS
卷 12, 期 4, 页码 -

出版社

MDPI
DOI: 10.3390/electronics12040851

关键词

fault tolerance analysis; open-circuit failures; multilevel dc-dc power converter; EV battery charging; bipolar dc grid

向作者/读者索取更多资源

This paper presents a bidirectional multilevel dc-dc power converter for electric vehicle battery charging. The power converter ensures continuous charging operation for EV batteries, regardless of the occurrence or absence of open-circuit failures in the bipolar dc grid. The proposed control algorithms and topology were validated through simulation and experimental results, analyzing different states of power semiconductors and considering various conditions of operation.
This paper presents a bidirectional multilevel dc-dc power converter for electric vehicle (EV) battery charging. The operating principle of the power converter was presented, analyzed, and experimentally validated under normal and fault conditions. The topology under study was integrated into a bipolar dc grid through the split dc-link of the bidirectional multilevel dc-dc power converter. Considering the failures that can occur in the bipolar dc grid, i.e., in each wire of the bipolar dc grid (positive, negative, and neutral), it was experimentally verified that the dc-dc power converter ensures that the EV battery-charging process continues, regardless of the occurrence or absence of open-circuit failures. In light of this fact, the proposed control algorithms and the presented topology were validated through a set of considerable simulation and experimental results, analyzing the distinct states of the power semiconductors, which compose the bidirectional multilevel dc-dc power converter, for distinct conditions of operation. The developed laboratory prototype of the bidirectional multilevel dc-dc power converter for EV battery charging, which was implemented to obtain the experimental results, is described in detail in this paper. The experimental validation was carried out for the main different fault conditions in the bipolar dc grid in terms of open-circuit failures and, moreover, considering the steady-state and transient-state operations of the dc-dc power converter. The experimental analysis demonstrated that even in the presence of failures in the positive, negative, or neutral wires of the bipolar dc grid, the bidirectional multilevel dc-dc power converter guarantees the correct EV battery-charging operation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据