4.6 Review

The accuracy of ultrasound-guided fine-needle aspiration and core needle biopsy in diagnosing axillary lymph nodes in women with breast cancer: a systematic review and meta-analysis

期刊

FRONTIERS IN ONCOLOGY
卷 13, 期 -, 页码 -

出版社

FRONTIERS MEDIA SA
DOI: 10.3389/fonc.2023.1166035

关键词

meta-analysis; fine-needle aspiration; core needle biopsy; axillary lymph nodes; diagnostic accuracy

类别

向作者/读者索取更多资源

This study evaluates the diagnostic accuracy of ultrasound-guided fine needle aspiration (US-FNA) and core needle biopsy (US-CNB) for detecting axillary lymph nodes in women with breast cancer. The results indicate that both US-FNA and US-CNB have high accuracy for suspicious axillary lymph nodes.
Background: This study evaluates the diagnostic accuracy of ultrasound-guided fine needle aspiration (US-FNA) and core needle biopsy (US-CNB) for detecting axillary lymph nodes in women with breast cancer.Methods: Eligible studies and pertinent literature resources were identified in Cochrane, PubMed, Embase, CNKI, VIP, and Wanfang databases using subject-specific keywords. Study outcomes were tested for heterogeneity, and meta-analyses were performed to estimate sensitivity, specificity, and diagnostic odds ratios (DORs). The summary receiver operating characteristic (SROC) curve analysis was also performed.Results: A total of 22 studies involving 3,548 patients were included to evaluate the diagnostic accuracy of US-FNA and 11 studies involving 758 patients were included to evaluate the diagnostic accuracy of US-CNB in identifying axillary lymph nodes in women with breast cancer. The accuracy of US-FNA in identifying suspicious axillary lymph nodes was as follows: overall sensitivity, 79% (95% CI: 73%-84%); global specificity, 96% (95% CI: 92%-98%); overall positive likelihood ratio, 18.55 (95% CI: 10.53-32.69); overall negative likelihood ratio, 0.22 (95% CI: 0.17-0.28); DOR, 71.68 (95% CI: 37.19-138.12); and the area under the SROC curve, 0.94 (95% CI: 0.92-0.96). The accuracy of US-CNB in identifying suspicious axillary lymph nodes was as follows: overall sensitivity, 85% (95% CI: 81%-89%); global specificity, 93% (95% CI: 87%-96%); overall positive likelihood ratio, 11.88 (95% CI: 6.56-21.50); overall negative likelihood ratio, 0.16 (95% CI: 0.12-0.21); overall DOR, 66.83 (95% CI: 33.28-134.21), and the area under SROC curve 0.96 (95% CI: 0.94-0.97).Conclusions: The results indicate that both US-FNA and US-CNB have high accuracy for suspicious axillary lymph nodes.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据