4.7 Article

The Early Effects on Tricuspid Annulus and Right Chambers Dimensions in Successful Tricuspid Valve Bicuspidization

期刊

JOURNAL OF CLINICAL MEDICINE
卷 12, 期 12, 页码 -

出版社

MDPI
DOI: 10.3390/jcm12124093

关键词

three-dimensional echocardiography; tricuspid annulus; bicuspidization; tricuspid valve quantification

向作者/读者索取更多资源

This study aimed to evaluate the reduction of tricuspid annulus (TA) and right heart chamber dimensions after bicuspidization surgery. The results showed that bicuspidization resulted in a significant reduction in TA and right chamber parameters, but did not change the tethering parameters of the tricuspid valve (TV) leaflets. Additionally, the parameters measured by three-dimensional transesophageal echocardiography (TOE) under general anesthesia were larger than those obtained by three-dimensional transthoracic echocardiography (TTE) before surgery.
Background: It is unclear to what degree of tricuspid annulus (TA) reduction is necessary to achieve good postoperative results in surgical bicuspidization. The study aimed to evaluate TA and right heart chamber's dimensions before and after heart surgery; and to compare TA parameters assessed by different modalities. Methods: Forty patients underwent mitral valve surgery with or without concomitant tricuspid valve (TV) bicuspidization. Preoperative and postoperative measurements of TA dimensions were performed prospectively using two-dimensional (2D) and three-dimensional (3D) transthoracic echocardiography (TTE). Additionally, preoperative transesophageal echocardiography (TOE) was performed in the operating room prior to surgery. Results: All patients had no or mild TR immediately after surgery. There was a significant reduction in 2D and 3D parameters of the TV and right chambers in the TV bicuspidization group. However, TV leaflets' tethering parameters did not change significantly. Preoperative 3D TTE measurements were smaller than those obtained through 3D TOE in the operation room, before surgery under general anesthesia. The 2D systolic apical 4Ch diameter and the parasternal short axis diameter mainly represent the 3D minor axis of the TA and are smaller than its 3D major axis. Conclusions: Although bicuspidization results in a one-third reduction of the TV area, tethering of the TV leaflets remains unchanged. Moreover, 3D TOE parameters of the TV under general anesthesia are larger than preoperative 3D TTE measurements. Conventional 2D measurements are insufficient for evaluating the maximum diameter of the TA.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据