Feasibility and Accuracy of Noninvasive Continuous Arterial Pressure Monitoring during Transcatheter Atrial Fibrillation Ablation

期刊

JOURNAL OF CLINICAL MEDICINE
卷 12, 期 6, 页码 -

出版社

MDPI
DOI: 10.3390/jcm12062388

关键词

atrial fibrillation ablation; arterial pressure; blood pressure; ClearSight; noninvasive continuous arterial pressure monitoring

向作者/读者索取更多资源

In patients undergoing AF ablation, continuous noninvasive blood pressure (CNBP) monitoring with the ClearSight device showed acceptable agreement with invasive radial arterial blood pressure (IBP) monitoring, suggesting potential clinical implications.
Introduction: Transcatheter atrial fibrillation (AF) ablation is still carried out with continuous invasive radial arterial blood pressure (IBP) monitoring in many centers. Continuous noninvasive blood pressure (CNBP) measurement using the volume-clamp method is a noninvasive alternative method used in ICU. No data on CNBP reliability are available in the electrophysiology lab during AF ablation, where rhythm variations are common. Background: The objective of the present study was to compare continuous noninvasive arterial pressure measured with the ClearSight device (Edwards Lifesciences, Irvine, CA, USA) with invasive radial artery pressure used as the reference method during AF ablation. Methods: We prospectively enrolled 55 consecutive patients (age 62 +/- 11 years, 80% male) undergoing transcatheter AF ablation (62% paroxysmal, 38% persistent) at our center. Standard of care IBP monitoring via a radial cannula and a contralateral noninvasive finger volume-clamp CNBP measurement device were positioned simultaneously in all patients for the entire procedure. Bland-Altman analysis was used to analyze the agreement between the two techniques. Results: A total of 1219 paired measurements for systolic, diastolic, and mean arterial pressure were obtained in 55 subjects, with a mean (SD) of 22 (9) measurements per patient. The mean bias (SD) was -12.97 (13.89) mmHg for systolic pressure (level of agreement -14.24-40.20; correlation coefficient 0.84), -1.85 (8.52) mmHg for diastolic pressure (level of agreement -18.54-14.84; correlation coefficient 0.77) and 2.31 (8.75) mmHg for mean pressure (level of agreement -14.84-19.46; correlation coefficient 0.85). Conclusion: In patients undergoing AF ablation, CNBP monitoring with the ClearSight device showed acceptable agreement with IBP monitoring. Larger studies are needed to confirm the potential clinical implications of continuous noninvasive BP monitoring during AF ablation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据