4.6 Article

All-Nontoxic Fluorescent Probe for Biothiols and Its Clinical Applications for Real-Time Glioblastoma Visualization

期刊

ACS SENSORS
卷 8, 期 4, 页码 1723-1732

出版社

AMER CHEMICAL SOC
DOI: 10.1021/acssensors.3c00004

关键词

fluorescent probe; reaction-based probe; biothiol sensing; glioblastoma; image-guided surgery

向作者/读者索取更多资源

Fluorescence-guided surgery (FSG) is a surgical method that uses fluorescent materials to selectively visualize tumor sites. However, commercially available fluorescent materials have shown serious adverse effects. A new nontoxic fluorescent probe called NPO-o-Pyr has been developed for real-time human glioblastoma visualization. It has high specificity and sensitivity, fast response time, and high biocompatibility. NPO-o-Pyr can overcome the limitations of current fluorescent probes and become a new substitute in FSG.
Fluorescence-guided surgery (FSG) is a surgical method to selectively visualize the tumor site using fluorescent materials with instrumental setups in the operation rooms. It has been widely used in the surgery of brain tumors, such as glioblastoma (GBM), which is difficult to distinguish from normal tissue. Although FSG is crucial for GBM surgery, the commercially available fluorescent materials for FSG have shown serious adverse effects. To satisfy the clinical demand, we recently reported reaction-based fluorescent probes based on a 4-chloro-7-nitrobenzofurazan (NBD) fluorophore that can detect cysteine (Cys) and homocysteine (Hcy), a biomarker of GBM, and their applications for the GBM diagnosis and FSG. However, our probes have cellular toxicity issues arising from the leaving group (LG) that is generated after the reaction of the fluorescent probe and the analytes. In this study, we disclosed a nontoxic fluorescent probe for sensing biothiols and their clinical applications for real-time human glioblastoma visualization. Systematic toxicity analysis of several LGs was conducted on several cell lines. Among the LGs, 2hydroxy-pyridine showed negligible toxicity, and its fluorescent probe derivative (named NPO-o-Pyr) showed high specificity and sensitivity (LOD: 0.071 ppm for Cys; 0.189 ppm for Hcy), a fast response time (<5 min) to Cys and Hcy, and high biocompatibility. In addition, NPO-o-Pyr can significantly detect the GBM site both in actual clinical samples as well as in the GBM-xenografted mouse model. We are confident that NPO-o-Pyr will become a new substitute in FSG due to its capability to overcome the limitations of the current fluorescent probes.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据