4.5 Article

Gadolinium K-edge angiography with a spectral photon counting CT in atherosclerotic rabbits

期刊

DIAGNOSTIC AND INTERVENTIONAL IMAGING
卷 104, 期 10, 页码 490-499

出版社

ELSEVIER MASSON, CORP OFF
DOI: 10.1016/j.diii.2023.05.002

关键词

CT-angiography; Gadolinium based contrast agent; K-edge imaging; Spectral photon counting CT

向作者/读者索取更多资源

The feasibility of gadolinium-K-edge-angiography (angio-Gd-K-edge) with gadolinium-based contrast agents (GBCAs) using spectral photon counting CT (SPCCT) was investigated in atherosclerotic rabbits. The study showed that angio-Gd-K-edge allowed visualization of target vessels and reliable measurement of their diameters.
Purpose: The purpose of this study was to investigate the feasibility of gadolinium-K-edge-angiography (angio-Gd-K-edge) with gadolinium-based contrast agents (GBCAs) as obtained with spectral photon counting CT (SPCCT) in atherosclerotic rabbits.Materials and methods: Seven atherosclerotic rabbits underwent angio-SPCCT acquisitions with two GBCAs, with similar intravenous injection protocol. Conventional and angio-Gd-K-edge images were reconstructed with the same parameters. Regions of interest were traced in different locations of the aorta and its branches. Hounsfield unit values, Gd concentrations, signal-to-noise (SNR) and contrast-to-noise (CNR) were calculated and compared. The maximum diameter and the diameter of the aorta in regard to atherosclerotic plaques were measured by two observers. Images were subjectively evaluated regarding vessels' enhancement, artefacts, border sharpness and overall image quality.Results: In the analyzable six rabbits, Gd-K-edge allowed visualization of target vessels and no other structures. HU values and Gd concentrations were greatest in the largest artery (descending aorta, 5.6 +/- 0.8 [SD] mm), and lowest in the smallest (renal arteries, 2.1 +/- 0.3 mm). While greater for conventional images, CNR and SNR were satisfactory for both images (all P < 0.001). For one observer there were no statistically significant differences in either maximum or plaque-diameters (P = 0.45 and all P > 0.05 in post-hoc analysis, respectively). For the second observer, there were no significant differences for images reconstructed with the same parameters (all P < 0.05). All subjective criteria scored higher for conventional images compared to K-edge (all P < 0.01), with the highest scores for enhancement (4.3-4.4 vs. 3.1-3.4).Conclusion: With SPCCT, angio-Gd-K-edge after injection of GBCAs in atherosclerotic rabbits is feasible and allows for angiography-like visualization of small arteries and for the reliable measurement of their diameters.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据