Accuracy of the Third Generation of a 14-Day Continuous Glucose Monitoring System

期刊

DIABETES THERAPY
卷 14, 期 4, 页码 767-776

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s13300-023-01385-6

关键词

FSL3 CGM system; FSL2 CGM system; Continuous glucose monitoring; Self-monitoring blood glucose; YSI reference

向作者/读者索取更多资源

This study evaluated the performance of the FreeStyle Libre (R) 3 continuous glucose monitoring system (FSL3) and compared it to different reference glucose values. The results showed that the FSL3 demonstrated accurate performance during the 14-day sensor wear period.
IntroductionWe have evaluated the performance of the FreeStyle Libre (R) 3 continuous glucose monitoring system (FSL3) compared to (1) the venous plasma reference for participants aged >= 6 years and (2) the fingerstick capillary blood glucose (BG) reference for pediatric participants aged 4 and 5 years. The analytical performance of the third-generation factory-calibrated FSL3 CGM system was compared to the plasma venous blood glucose reference using the YSI 2300 STAT PLUS Glucose and Lactate Analyzer (the YSI reference) and the self-monitoring blood glucose (SMBG) reference for participants aged >= 6 years and participants aged 4 and 5 years, respectively.MethodsA total of 108 participants aged >= 4 years with type 1 or type 2 diabetes from four sites in the USA were enrolled in the study. The data of 100 participants were ultimately evaluated. Adult participants (aged >= 18 years) participated in three in-clinic sessions, and pediatric participants (aged 4-17 years) participated in up to two in-clinic sessions, all stratified to provide data for days 1, 2, 3, 7, 8, 9, 12, 13 or 14 of sensor wear. Performance evaluation included accuracy measures, such as proportion of CGM values that fell within +/- 20% or +/- 20 mg/dL (1.1 mmol/L) of the reference glucose values, and difference measures, such as the mean absolute relative difference (MARD) between the CGM and reference values.ResultsData from the 100 study participants were analyzed. The overall MARD was 7.8%, and 93.4% of the CGM values were within +/- 20% or +/- 20 mg/dL of the YSI reference for participants aged >= 6 years, with 6845 CGM-YSI matched pairs. The performance was stable over the 14-day wear period. For participants aged 4-5 years, MARD was 10.0%, and 88.9% of the CGM values were within 20%/20 mg/dL compared to a SMBG reference. No serious adverse events were reported.ConclusionsThe FSL3 CGM system demonstrated accurate performance across the dynamic glycemic range during the 14-day sensor wear period.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据