4.6 Article

Predicting DWI-FLAIR mismatch on NCCT: the role of artificial intelligence in hyperacute decision making

期刊

FRONTIERS IN NEUROLOGY
卷 14, 期 -, 页码 -

出版社

FRONTIERS MEDIA SA
DOI: 10.3389/fneur.2023.1201223

关键词

artificial intelligence; DWI; FLAIR; DWI-FLAIR mismatch; non-contrast computed tomography

向作者/读者索取更多资源

In this study, a deep learning model based on the nnU-net architecture was used to predict ischemic lesions visible on diffusion-weighted imaging (DWI) and fluid-attenuated inversion recovery (FLAIR) images using non-contrast computed tomography (NCCT) images. The results showed that the evaluation accuracy of DWI-FLAIR mismatch improved when using NCCT images in the subgroup with lesion volume greater than or equal to 15 mL.
BackgroundThe presence of diffusion-weighted imaging (DWI) and fluid-attenuated inversion recovery (FLAIR) mismatch was used to determine eligibility for intravenous thrombolysis in clinical trials. However, due to the restricted availability of MRI and the ambiguity of image assessment, it is not widely implemented in clinical practice. MethodsA total of 222 acute ischemic stroke patients underwent non-contrast computed tomography (NCCT), DWI, and FLAIR within 1 h of one another. Human experts manually segmented ischemic lesions on DWI and FLAIR images and independently graded the presence of DWI-FLAIR mismatch. Deep learning (DL) models based on the nnU-net architecture were developed to predict ischemic lesions visible on DWI and FLAIR images using NCCT images. Inexperienced neurologists evaluated the DWI-FLAIR mismatch on NCCT images without and with the model's results. ResultsThe mean age of included subjects was 71.8 & PLUSMN; 12.8 years, 123 (55%) were male, and the baseline NIHSS score was a median of 11 [IQR, 6-18]. All images were taken in the following order: NCCT - DWI - FLAIR, starting after a median of 139 [81-326] min after the time of the last known well. Intravenous thrombolysis was administered in 120 patients (54%) after NCCT. The DL model's prediction on NCCT images revealed a Dice coefficient and volume correlation of 39.1% and 0.76 for DWI lesions and 18.9% and 0.61 for FLAIR lesions. In the subgroup with 15 mL or greater lesion volume, the evaluation of DWI-FLAIR mismatch from NCCT by inexperienced neurologists improved in accuracy (from 0.537 to 0.610) and AUC-ROC (from 0.493 to 0.613). ConclusionThe DWI-FLAIR mismatch may be reckoned using NCCT images through advanced artificial intelligence techniques.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据