4.6 Article

The Cyclic Fatigue Resistance of Different Lengths of CM Gold Wire and CM Blue Wire NiTi Alloy Endodontic Rotary Files: An In Vitro Study

相关参考文献

注意:仅列出部分参考文献,下载原文获取全部文献信息。
Article Environmental Sciences

Comparative Study of the SEM Evaluation, EDX Assessment, Morphometric Analysis, and Cyclic Fatigue Resistance of Three Novel Brands of NiTi Alloy Endodontic Files

Vicente Faus-Matoses et al.

Summary: In this study, the performance of three novel brands of nickel-titanium endodontic files was compared, and it was found that Smarttrack exhibited higher resistance to cyclic fatigue. This is due to its reciprocating movement and metallurgical composition.

INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH (2022)

Article Medicine, General & Internal

Effect of Rotational Speed on the Resistance of NiTi Alloy Endodontic Rotary Files to Cyclic Fatigue-An In Vitro Study

Vicente Faus-Matoses et al.

Summary: The present study evaluated and compared the function of the rotational speed of NiTi alloy endodontic rotary files in terms of their resistance to dynamic cyclic fatigue. The results showed that NiTi alloy endodontic rotary files with reciprocating movement at a lower speed exhibited greater resistance to fatigue.

JOURNAL OF CLINICAL MEDICINE (2022)

Article Chemistry, Multidisciplinary

The Effect of Taper and Apical Diameter on the Cyclic Fatigue Resistance of Rotary Endodontic Files Using an Experimental Electronic Device

Vicente Faus-Llacer et al.

Summary: This study analyzed the impact of the taper and apical diameter of NiTi endodontic rotary files on dynamic cyclic fatigue resistance. The findings revealed that increasing the apical diameter and taper of the files decreased their resistance to cyclic fatigue.

APPLIED SCIENCES-BASEL (2021)

Article Dentistry, Oral Surgery & Medicine

Design, metallurgical features, mechanical performance and canal preparation of six reciprocating instruments

J. N. R. Martins et al.

Summary: This study compared six reciprocating instruments in terms of their geometric design, metallurgical characteristics, mechanical behavior, and ability to prepare root canals. While the instruments had similarities in metal composition and unprepared canal area, they showed differences in phase transformation temperatures and geometric design. The study found that there were variations in the overall geometric design, phase transformation temperatures, and mechanical resistance parameters among the instruments.

INTERNATIONAL ENDODONTIC JOURNAL (2021)

Article Medicine, General & Internal

Influence of the Geometrical Cross-Section Design on the Dynamic Cyclic Fatigue Resistance of NiTi Endodontic Rotary Files-An In Vitro Study

Vicente Faus-Llacer et al.

Summary: This study analyzed and compared the influence of geometrical cross-section design on the dynamic cyclic fatigue resistance of NiTi endodontic rotary files. The results showed that the double S-shaped cross-section design demonstrated higher fatigue resistance compared to other cross-section designs.

JOURNAL OF CLINICAL MEDICINE (2021)

Article Dentistry, Oral Surgery & Medicine

Effect of Shaft Length on the Torsional Resistance of Rotary Nickel-titanium Instruments

Vasfiye Isik et al.

JOURNAL OF ENDODONTICS (2020)

Article Medicine, General & Internal

Influence of the Pecking Motion Frequency on the Cyclic Fatigue Resistance of Endodontic Rotary Files

Alvaro Zubizarreta-Macho et al.

JOURNAL OF CLINICAL MEDICINE (2020)

Article Dentistry, Oral Surgery & Medicine

Mechanical Properties of Glide Path Preparation Instruments with Different Pitch Lengths

Dana Al Raeesi et al.

JOURNAL OF ENDODONTICS (2018)

Article Dentistry, Oral Surgery & Medicine

Cyclic Fatigue Resistance of Reciproc Blue, Reciproc, and WaveOne Gold Reciprocating Instruments

Cangul Keskin et al.

JOURNAL OF ENDODONTICS (2017)

Article Dentistry, Oral Surgery & Medicine

Effects of Pitch Length and Heat Treatment on the Mechanical Properties of the Glide Path Preparation Instruments

Sang Won Kwak et al.

JOURNAL OF ENDODONTICS (2016)

Review Dentistry, Oral Surgery & Medicine

Current Challenges and Concepts of the Thermomechanical Treatment of Nickel-Titanium Instruments

Ya Shen et al.

JOURNAL OF ENDODONTICS (2013)

Article Dentistry, Oral Surgery & Medicine

Differences in Cyclic Fatigue Resistance at Apical and Coronal Levels of Reciproc and Wave One New Files

Ana Arias et al.

JOURNAL OF ENDODONTICS (2012)

Article Dentistry, Oral Surgery & Medicine

Flexural Stiffness and Stresses in Nickel-Titanium Rotary Files for Various Pitch and Cross-sectional Geometries

Antheunis Versluis et al.

JOURNAL OF ENDODONTICS (2012)

Review Dentistry, Oral Surgery & Medicine

A Review of Cyclic Fatigue Testing of Nickel-Titanium Rotary Instruments

Gianluca Plotino et al.

JOURNAL OF ENDODONTICS (2009)

Article Dentistry, Oral Surgery & Medicine

Cyclic Fatigue Analysis of a New Generation of Nickel Titanium Rotary Instruments

C. Michael Larsen et al.

JOURNAL OF ENDODONTICS (2009)

Article Dentistry, Oral Surgery & Medicine

Mechanical properties of a new and improved nickel-titanium alloy for endodontic use: an evaluation of file flexibility

Gianluca Gambarini et al.

ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY (2008)

Article Dentistry, Oral Surgery & Medicine

Effect of environment on low-cycle fatigue of a nickel-titanium instrument

Gary S. P. Cheung et al.

JOURNAL OF ENDODONTICS (2007)

Article Dentistry, Oral Surgery & Medicine

Cyclic fatigue of different nickel-titanium endodontic rotary instruments

Teresa Roberta Tripi et al.

ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY (2006)

Article Dentistry, Oral Surgery & Medicine

Effect of cyclic fatigue on static fracture loads in ProTaper nickel-titanium rotary instruments

CJ Ullmann et al.

JOURNAL OF ENDODONTICS (2005)

Article Dentistry, Oral Surgery & Medicine

Dynamic torque and apical forces of ProFile .04 rotary instruments during preparation of curved canals

OA Peters et al.

INTERNATIONAL ENDODONTIC JOURNAL (2002)

Article Dentistry, Oral Surgery & Medicine

Influence of structure on nickel-titanium endodontic instruments failure

G Kuhn et al.

JOURNAL OF ENDODONTICS (2001)

Article Dentistry, Oral Surgery & Medicine

Defects in rotary nickel-titanium files after clinical use

B Sattapan et al.

JOURNAL OF ENDODONTICS (2000)