Development of silver nanoparticles and aptamer conjugated biosensor for rapid detection of E. coli in a water sample

期刊

3 BIOTECH
卷 13, 期 7, 页码 -

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s13205-023-03663-3

关键词

Biosensor; Electrochemical; Silver nanoparticles; Screen printed electrode; Bacteria detection

向作者/读者索取更多资源

A simple, rapid, and sensitive electrochemical biosensor based on a screen-printed carbon electrode was developed for onsite detection of E. coli. The effect of aptamer conjugation and PBS buffer solution on the colloidal stability of AgNPs was analyzed. The biosensor showed good sensitivity with a limit of detection of 150 CFU/ml and selectivity for E. coli compared to other bacteria. It also exhibited good reproducibility, stability, and high recoveries during sensitivity validation.
A simple, rapid, and sensitive electrochemical biosensor based on a screen-printed carbon electrode (SPCE) was developed for onsite detection of E. coli in real time. This work analyzed the effect of aptamer conjugation and PBS buffer solution on the colloidal stability of the silver nanoparticles (AgNPs). Aggregations of the AgNPs after aptamer conjugation in PBS buffer were observed from the particle size distribution analysis. The AgNP-aptamer conjugation and its affinity towards E. coli (DH5 alpha) were confirmed by UV-visible spectrophotometry, which showed a linear increment in the absorption with increasing E.coli concentration. The screen-printed carbon electrodes were modified by drop-casting of AgNPs, which were used as an effective immobilization platform for E. coli-specific aptamers. The modified electrode's surface modification and redox behavior were characterized using cyclic voltammetry. Finally, E. coli was detected using differential pulse voltammetry with an optimized incubation time of 15 min. The developed biosensors showed a linear decrease in current intensity with an increase in the concentration of E. coli. The biosensor had a relative standard deviation (RSD) of 6.91% (n = 3), which showed good reproducibility. The developed biosensors are highly sensitive and have a limit of detection (LOD) as low as 150 CFU/ml. The biosensor showed good selectivity for E.coli coli when comparing the signal response obtained for bacteria other than E.coli. Also, the biosensor was found stable for four weeks at room temperature and showed high recoveries from 95.27% to 107% during the tap water sensitivity validation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据