4.7 Article

Insight into over Repair of Hot Carrier Degradation by GIDL Current in Si p-FinFETs Using Ultra-Fast Measurement Technique

期刊

NANOMATERIALS
卷 13, 期 7, 页码 -

出版社

MDPI
DOI: 10.3390/nano13071259

关键词

reliability; hot carrier degradation (HCD); Si p-FinFETs; gate-induced drain leakage (GIDL); recovery; oxide trap generation; energy distribution

向作者/读者索取更多资源

In this article, an experimental study was conducted on the gate-induced drain leakage (GIDL) current repairing worst hot carrier degradation (HCD) in Si p-FinFETs using an ultra-fast measurement (UFM) technique. It was found that increasing the GIDL bias from 3 V to 4 V achieved a 114.7% V-T recovery ratio from HCD. The over-repair phenomenon of HCD by UFM GIDL was discussed through oxide trap behaviors. The results provide insights into the transistor repairing technique and its implications for the reliable operation of ICs.
In this article, an experimental study on the gate-induced drain leakage (GIDL) current repairing worst hot carrier degradation (HCD) in Si p-FinFETs is investigated with the aid of an ultra-fast measurement (UFM) technique (similar to 30 mu s). It is found that increasing GIDL bias from 3 V to 4 V achieves a 114.7% V-T recovery ratio from HCD. This over-repair phenomenon of HCD by UFM GIDL is deeply discussed through oxide trap behaviors. When the applied gate-to-drain GIDL bias reaches 4 V, a significant electron trapping and interface trap generation of the fresh device with GIDL repair is observed, which greatly contributes to the approximate 114.7% over-repair V-T ratio of the device under worst HCD stress (-2.0 V, 200 s). Based on the TCAD simulation results, the increase in the vertical electric field on the surface of the channel oxide layer is the direct cause of an extraordinary electron trapping effect accompanied by the over-repair phenomenon. Under a high positive electric field, a part of channel electrons is captured by oxide traps in the gate dielectric, leading to further V-T recovery. Through the discharge-based multi-pulse (DMP) technique, the energy distribution of oxide traps after GIDL recovery is obtained. It is found that over-repair results in a 34% increment in oxide traps around the conduction energy band (E-c) of silicon, which corresponds to a higher stabilized V-T shift under multi-cycle HCD-GIDL tests. The results provide a trap-based understanding of the transistor repairing technique, which could provide guidance for the reliable long-term operation of ICs.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据