4.3 Article

First insights into the role of wall shear stress in the development of a distal stent graft induced new entry through computational fluid dynamics simulations

期刊

JOURNAL OF THORACIC DISEASE
卷 15, 期 2, 页码 281-290

出版社

AME PUBLISHING COMPANY
DOI: 10.21037/jtd-22-1206

关键词

Wall shear stress (WSS); computational fluid dynamics simulation; distal stent graft induced new entry (dSINE); frozen elephant trunk (FET); aortic dissection

向作者/读者索取更多资源

Distal stent graft induced new entry (dSINE) is an emerging complication after frozen elephant trunk (FET) procedure. This computational fluid dynamics (CFD) study investigated the role of wall shear stress (WSS) after the development of dSINE based on hemodynamic changes. The results suggest that the increase in WSS may play an important role in weakening the aortic wall and other adverse events similar to aortic rupture.
Background: Distal stent graft induced new entry (dSINE) is an emerging complication after frozen elephant trunk (FET) procedure. The aim of this computational fluid dynamics (CFD) study was to investigate the role of wall shear stress (WSS) after the development of dSINE based on hemodynamic changes.Methods: Aortic diameter and WSS of five patients who developed a dSINE after FET procedure were retrospectively analyzed before and after the occurrence of dSINE. Patient-specific 3-dimentional surface models of the aortic lumen were reconstructed from computed tomography angiographic datasets (pre dSINE: n=5, dSINE: n=5) to perform steady-state CFD simulations with laminar blood flow and zero pressure outlet conditions. WSS was calculated at the level of the stent graft (SG), the landing zone of the SG and at a location further distal to the SG, as well as on the outer and inner curvature of the aorta from SG center to its distal end.Results: Post dSINE occurrence, median WSS increased significantly from 0.87 [interquartile range (IQR): 0.83-1.03] to 1.55 (IQR: 1.09-2.70) Pa, (P=0.043) within the SG and from 1.22 (IQR: 0.81-1.44) to 1.76 (IQR: 1.55-3.60) Pa, (P=0.043) at the landing zone of the SG. A non-significant increase from 1.22 (IQR: 0.59-3.50) to 2.58 (IQR: 1.16-3.78) Pa, (P=0.686) further downstream was observed. WSS at the outer curvature of the SG was significantly higher compared to WSS at the inner curvature for dSINE. Conclusions: Adverse hemodynamic conditions in the form of elevated WSS consist inside and at the distal end of the SG as well as at the outer curvature of the aorta, which may contribute to weakening of the aortic wall. These new findings emphasize the relevance and potential of WSS in dSINE for additional adverse events, such as aortic rupture. Further prospective studies are warranted to explore if the combination of clinical parameters with WSS might be useful to decide which patients require an urgent reintervention in terms of a SG extension.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据