期刊
WATER
卷 15, 期 12, 页码 -出版社
MDPI
DOI: 10.3390/w15122230
关键词
selenium; drinking water; water treatment; wastewater treatment
The study aimed to examine the variation in selenium content in drinking water, raw water, and treated and raw wastewater in the city of Szczecin over a one-year period. The concentration of selenium was measured using the spectrofluorometric method with an emission wavelength of 518 nm and an excitation wavelength of 378 nm. The results showed that the amount of selenium in drinking water ranged from...
Selenium is a trace element that can be poisonous in small quantities. The aim of this study was to analyze the change in the content of selenium in drinking water, raw water, as well as treated and raw wastewater in an annual cycle in the city of Szczecin. The concentration of Se in samples was determined using the spectrofluorometric method at a 518 nm emission wavelength and a 378 nm excitation wavelength. The amount of selenium in drinking water ranged from
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐