The ratio of respiratory rate to diaphragm thickening fraction for predicting extubation success

期刊

BMC PULMONARY MEDICINE
卷 23, 期 1, 页码 -

出版社

BMC
DOI: 10.1186/s12890-023-02392-w

关键词

Diaphragm ultrasound; Ultrasound; Extubation; Weaning; Rapid shallow breathing index; Diaphragm thickening fraction; Diaphragmatic excursion

向作者/读者索取更多资源

This study aimed to evaluate the effectiveness of the respiratory rate to diaphragm thickening fraction (RR/DTF) ratio in predicting successful extubation. The study found that the RR/DTF was significantly lower in the successful extubation group compared to the extubation failure group. The study suggests using a cut-off point of 0.81 for the right RR/DTF to predict extubation success, and concludes that RR/DTF is more reliable than conventional or diaphragmatic parameters alone in predicting extubation success.
BackgroundSeveral parameters are used to predict successful extubation but their accuracy varies among studies. We hypothesized that combining conventional and diaphragmatic parameters would be more effective than using just one. Our primary objective was to evaluate the performance of the respiratory rate in relation to the diaphragm thickening fraction (RR/DTF) ratio to predict the success of extubation.MethodsWe enrolled 130 adult patients who required invasive mechanical ventilation, planned to be extubated, and used a spontaneous breathing trial (SBT) in the intensive care unit from July 2020 to April 2022. We measured the conventional parameters and the diaphragmatic parameters 2 h after SBT. The RR/DTF was calculated by dividing the respiratory rate (RR) by the diaphragm thickening fraction (DTF). The definition of weaning success is successful extubation within 48 h.ResultsOf 130 patients, 8 patients (6.2%) were reintubated within 48 h. The RR/DTF was significantly lower in the successful extubation group than in the extubation failure group (right hemidiaphragm; 0.47 (0.33-0.64) vs 1.1 (0.6-2.32), p < 0.001 and left hemidiaphragm; 0.45 (0.31-0.65) vs 0.78 (0.48-1.75), p < 0.001). The right RR/DTF using a cut-off point at <= 0.81 had a sensitivity of 87.7%, a specificity of 75%, and areas under the receiver operating characteristic curve (AUROC) of 0.762 for predicting successful extubation (p = 0.013). The sensitivity, specificity, and AUROC for predicting extubation success of right DTF at a cut-off point of >= 26.2% were 84.3%, 62.5%, and 0.775, respectively (p = 0.009).ConclusionThe RR/DTF ratio is a promising tool for predicting extubation outcome. Additionally, using RR/DTF was more reliable than conventional or diaphragmatic parameters alone in predicting extubation success.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据