4.6 Article

Micro-CT Evaluation of Microgaps at Implant-Abutment Connection

相关参考文献

注意:仅列出部分参考文献,下载原文获取全部文献信息。
Review Dentistry, Oral Surgery & Medicine

Oral health-related quality of life of patients rehabilitated with fixed and removable implant-supported dental prostheses

Ho-Yan Duong et al.

Summary: Dental implants have become the preferred option for prosthetic rehabilitation, but patient perceptions of oral health-related quality of life do not show overall superiority compared to conventional prosthetics. Patient expectations significantly affect treatment outcomes, and reconstructions supported by implants improve stability and function. However, there are discrepancies between patients' and clinicians' evaluations, especially in esthetic outcomes.

PERIODONTOLOGY 2000 (2022)

Article Chemistry, Physical

In Vitro Study of Preload Loss in Different Implant Abutment Connection Designs

Ana Sofia Vinhas et al.

Summary: The stability and integrity of the abutment-implant connection are crucial for the success of dental implants. Screw loosening can lead to various complications and affect osseointegration. In vitro studies are needed to evaluate the torque maintenance of different connections before and after loading.

MATERIALS (2022)

Article Dentistry, Oral Surgery & Medicine

A 5-year randomized controlled trial comparing zirconia-based versus metal-based implant-supported single-tooth restorations in the premolar region

Mandana Hosseini et al.

Summary: This study compared the biological, technical, aesthetic, and patient-reported outcomes of single-tooth implant-supported all-ceramic versus metal-ceramic restorations over a 5-year period. The results showed no significant differences between the two types of restorations in terms of biological, aesthetic, and patient-reported outcomes.

CLINICAL ORAL IMPLANTS RESEARCH (2022)

Review Chemistry, Physical

Titanium Dental Implants: An Overview of Applied Nanobiotechnology to Improve Biocompatibility and Prevent Infections

Rayane C. S. Silva et al.

Summary: This review discusses the use of titanium and its alloys in dental implant production, the common causes of implant failures, and the development of improved surfaces to enhance osseointegration. Surface modifications at the nanoscale and bioactivation with biological molecules have been found to promote faster healing compared to smooth surfaces. Additionally, gradual changes in the implant based on the insertion microenvironment may improve integration with soft and bone tissues, preventing infections and failures in osseointegration.

MATERIALS (2022)

Article Biochemistry & Molecular Biology

A Micro-CT Analysis of Initial and Long-Term Pores Volume and Porosity of Bioactive Endodontic Sealers

Mateusz Radwanski et al.

Summary: The evaluation of porosities within the interface of root canals obturated with bioactive endodontic sealers is important for long-term success. This study compared the volume and porosity of three sealers after initial and long-term storage. The results showed that the porosity of some sealers increased significantly after long-term storage, which could compromise the success of endodontic treatments.

BIOMEDICINES (2022)

Article Engineering, Biomedical

Synchrotron-based micro computed tomography investigation of the implant-abutment fatigue-induced microgap changes

Aimen Bagegni et al.

Summary: This study evaluated the effect of dynamic-loading on the microgap of the internal microgap of the IAC when different supratructure heights are applied. The results showed that regardless of the crown height, the microgap between the abutment and implant systematically decreased after loading in both butt-joint and internal-conical connections.

JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS (2021)

Article Chemistry, Physical

Effect of Fabrication Technique on the Microgap of CAD/CAM Cobalt-Chrome and Zirconia Abutments on a Conical Connection Implant: An In Vitro Study

Pedro Molinero-Mourelle et al.

Summary: The study found that milled Co-Cr abutments had the smallest microgaps, followed by Zirconia abutments, while sintered Co-Cr and cast Co-Cr abutments had larger microgaps. The abutment material and fabrication technique can affect the magnitude of the implant-abutment microgap.

MATERIALS (2021)

Article

Titanium Base Abutments in Implant Prosthodontics: A Literature Review

Ahmad M. Al-Thobity

European Journal of Dentistry (2021)

Review Materials Science, Multidisciplinary

Factors Influencing Marginal Bone Loss around Dental Implants: A Narrative Review

Jakub Kowalski et al.

Summary: This narrative review discusses the impact of implant-supported dental prostheses on peri-implant tissue, including factors influencing bone loss, properties of different materials, and advantages and disadvantages of various implant-abutment connections. The influence of implant and abutment surface at the transmucosal level on peri-implant soft tissue is highlighted. Finally, the biological aspect of abutment-implant connection is analyzed.

COATINGS (2021)

Review Imaging Science & Photographic Technology

Micro-CT for Biological and Biomedical Studies: A Comparison of Imaging Techniques

Kleoniki Keklikoglou et al.

Summary: This review discusses the strengths and weaknesses of common imaging techniques in biological and biomedical fields, while emphasizing the ability of micro-CT to create non-destructively 3D anatomical and morphological data in sub-micron resolution. The necessity to develop complementary methods with other imaging techniques to overcome limitations caused by each technique is also highlighted.

JOURNAL OF IMAGING (2021)

Article Medicine, General & Internal

Influence of Implant Connection, Abutment Design and Screw Insertion Torque on Implant-Abutment Misfit

Jorge Velez et al.

JOURNAL OF CLINICAL MEDICINE (2020)

Review Environmental Sciences

Review of the Mechanical Behavior of Different Implant-Abutment Connections

Ana Sofia Vinhas et al.

INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH (2020)

Review Materials Science, Multidisciplinary

Microcomputed tomography-based characterization of advanced materials: a review

L. Vasarhelyi et al.

MATERIALS TODAY ADVANCES (2020)

Article Dentistry, Oral Surgery & Medicine

Influence of Abutment Fabrication Method on 3D Fit at the Implant-Abutment Connection

Ilana Ramalho et al.

INTERNATIONAL JOURNAL OF PROSTHODONTICS (2020)

Article Dentistry, Oral Surgery & Medicine

Three-dimensional misfit between Ti-Base abutments and implants evaluated by replica technique

Karina Bergamo Cardoso et al.

JOURNAL OF APPLIED ORAL SCIENCE (2020)

Article Dentistry, Oral Surgery & Medicine

Clinical Evidence of OsseoSpeed EV Implants: A Retrospective Study and Characterization of the Newly Introduced System

Marco Toia et al.

INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY (2019)

Article Chemistry, Physical

Influence of the Elastic Modulus on the Osseointegration of Dental Implants

Aritza Brizuela et al.

MATERIALS (2019)

Article Dentistry, Oral Surgery & Medicine

Precision of the Connection Between Implant and Standard or Computer-Aided Design/Computer-Aided Manufacturing Abutments: A Novel Evaluation Method

Diego Lops et al.

INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS (2018)

Article Dentistry, Oral Surgery & Medicine

Histological and micro-CT analysis of peri-implant soft and hard tissue healing on implants with different healing abutments configurations

Andre Barbisan Souza et al.

CLINICAL ORAL IMPLANTS RESEARCH (2018)

Article Dentistry, Oral Surgery & Medicine

The influence of implant-abutment connection on the screw loosening and microleakage

Katsuhiro Tsuruta et al.

INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY (2018)

Review Dentistry, Oral Surgery & Medicine

Implant-Abutment Connections: A Review of Biologic Consequences and Peri-implantitis Implications

Yuya Sasada et al.

INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS (2017)

Review Dentistry, Oral Surgery & Medicine

Influences of microgap and micromotion of implant-abutment interface on marginal bone loss around implant neck

Yang Liu et al.

ARCHIVES OF ORAL BIOLOGY (2017)

Article Dentistry, Oral Surgery & Medicine

In vitro analysis of the microbiological sealing of tapered implants after mechanical cycling

Deceles Cristina Costa Alves et al.

CLINICAL ORAL INVESTIGATIONS (2016)

Article Dentistry, Oral Surgery & Medicine

Microbiome of titanium and zirconia dental implants abutments

Cassio do Nascimento et al.

DENTAL MATERIALS (2016)

Article Materials Science, Biomaterials

In Vitro Evaluation of Bacterial Leakage at Implant-Abutment Connection: An 11-Degree Morse Taper Compared to a Butt Joint Connection

Hooman Khorshidi et al.

INTERNATIONAL JOURNAL OF BIOMATERIALS (2016)

Article Dentistry, Oral Surgery & Medicine

Fatigue induced changes in conical implant-abutment connections

Kai Blum et al.

DENTAL MATERIALS (2015)

Article Dentistry, Oral Surgery & Medicine

Microcomputed Tomography-Based Assessment of Retrieved Dental Implants

Nathaniel Narra et al.

INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS (2015)

Review Medicine, General & Internal

Implant biomaterials: A comprehensive review

Monika Saini et al.

WORLD JOURNAL OF CLINICAL CASES (2015)

Article Dentistry, Oral Surgery & Medicine

Implants with Original and Non-Original Abutment Connections

Michel Gigandet et al.

CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH (2014)

Article Dentistry, Oral Surgery & Medicine

Microleakage of the prosthetic abutment/implant interface with internal and external connection: In vitro study

Carlos Larrucea Verdugo et al.

CLINICAL ORAL IMPLANTS RESEARCH (2014)

Article Dentistry, Oral Surgery & Medicine

A Pilot Study of Joint Stability at the Zirconium or Titanium Abutment/Titanium Implant Interface

Yeliz Cavusoglu et al.

INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS (2014)

Article Dentistry, Oral Surgery & Medicine

Changes in the Abutment-Implant Interface in Morse Taper Implant Connections After Mechanical Cycling: A Pilot Study

Sergio Alexandre Gehrke et al.

INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS (2014)

Review Engineering, Biomedical

Performance of conical abutment (Morse Taper) connection implants: A systematic review

Christian M. Schmitt et al.

JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A (2014)

Article Engineering, Biomedical

Implant-abutment connections: influence of the design on the microgap and their fatigue and fracture behavior of dental implants

F. J. Gil et al.

JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE (2014)

Article Dentistry, Oral Surgery & Medicine

Implants With Internal Hexagon and Conical Implant-Abutment Connections: An In Vitro Study of the Bacterial Contamination

Simonetta D'Ercole et al.

JOURNAL OF ORAL IMPLANTOLOGY (2014)

Article Dentistry, Oral Surgery & Medicine

Influence of the implant-abutment connection design and diameter on the screw joint stability

Hyon-Mo Shin et al.

JOURNAL OF ADVANCED PROSTHODONTICS (2014)

Review Dentistry, Oral Surgery & Medicine

Current trends in dental implants

Laura Gaviria et al.

JOURNAL OF THE KOREAN ASSOCIATION OF ORAL AND MAXILLOFACIAL SURGEONS (2014)

Article Dentistry, Oral Surgery & Medicine

In Vitro Evaluation of Leakage at Implant-Abutment Connection of Three Implant Systems Having the Same Prosthetic Interface Using Rhodamine B

Antoine Berberi et al.

INTERNATIONAL JOURNAL OF DENTISTRY (2014)

Article Dentistry, Oral Surgery & Medicine

Influence of the casting technique and dynamic loading on screw detorque and misfit of single unit implant-supported prostheses

Claudia Lopes Brilhante Bhering et al.

ACTA ODONTOLOGICA SCANDINAVICA (2013)

Article Dentistry, Oral Surgery & Medicine

The Role of Implant/Abutment System on Torque Maintenance of Retention Screws and Vertical Misfit of Implant-Supported Crowns Before and After Mechanical Cycling

Juliana Ribeiro Pala Jorge et al.

INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS (2013)

Article Engineering, Biomedical

Qualitative assessment of microstructure and Hertzian indentation failure in biocompatible glass ionomer cements

Kun V. Tian et al.

JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE (2012)

Article Dentistry, Oral Surgery & Medicine

Evaluation of Microgap Size and Microbial Leakage in the Connection Area of 4 Abutments With Straumann (ITI) Implant

Mansoor Rismanchian et al.

JOURNAL OF ORAL IMPLANTOLOGY (2012)

Article Dentistry, Oral Surgery & Medicine

Bacterial Leakage in Implants With Different Implant-Abutment Connections: An In Vitro Study

Bartolomeo Assenza et al.

JOURNAL OF PERIODONTOLOGY (2012)

Article Dentistry, Oral Surgery & Medicine

Peri-Implant Crestal Bone Loss: A Putative Mechanism

Yuko Ujiie et al.

INTERNATIONAL JOURNAL OF DENTISTRY (2012)

Article Dentistry, Oral Surgery & Medicine

Effect of cyclic load on vertical misfit of prefabricated and cast implant single abutment

Rudys Rodolfo de Jesus Tavarez et al.

Journal of Applied Oral Science (2011)

Article Dentistry, Oral Surgery & Medicine

Sealing Capability and SEM Observation of the Implant-Abutment Interface

Fabio C. Lorenzoni et al.

INTERNATIONAL JOURNAL OF DENTISTRY (2011)

Article Dentistry, Oral Surgery & Medicine

Bacterial Colonization of the Dental Implant Fixture-Abutment Interface: An In Vitro Study

Michael Tesmer et al.

JOURNAL OF PERIODONTOLOGY (2009)

Article Dentistry, Oral Surgery & Medicine

Implant-abutment interface design affects fatigue and fracture strength of implants

Lars Steinebrunner et al.

CLINICAL ORAL IMPLANTS RESEARCH (2008)

Article Dentistry, Oral Surgery & Medicine

Marginal fit and microgaps of implant-abutment interface with internal anti-rotation configuration

Takuma Tsuge et al.

DENTAL MATERIALS JOURNAL (2008)

Article Dentistry, Oral Surgery & Medicine

Role of the microgap between implant and abutment: A retrospective histologic evaluation in monkeys

A Piattelli et al.

JOURNAL OF PERIODONTOLOGY (2003)