4.6 Article

Automated segmentation and quantification of calcified drusen in 3D swept source OCT imaging

期刊

BIOMEDICAL OPTICS EXPRESS
卷 14, 期 3, 页码 1292-1306

出版社

Optica Publishing Group
DOI: 10.1364/BOE.485999

关键词

-

向作者/读者索取更多资源

This paper presents the development of an automated algorithm for segmenting and quantifying calcified drusen on SS-OCT images. The algorithm utilizes the higher scattering property of calcified drusen and combines the optical attenuation coefficient (OAC) within drusen and the choroidal hypotransmission defects (hypoTDs) under drusen to achieve accurate segmentation. The study demonstrates good agreement between the automated method and human expert graders in identifying the area of calcified drusen.
Qualitative and quantitative assessments of calcified drusen are clinically important for determining the risk of disease progression in age-related macular degeneration (AMD). This paper reports the development of an automated algorithm to segment and quantify calcified drusen on swept-source optical coherence tomography (SS-OCT) images. The algorithm leverages the higher scattering property of calcified drusen compared with soft drusen. Calcified drusen have a higher optical attenuation coefficient (OAC), which results in a choroidal hypotransmission defect (hypoTD) below the calcified drusen. We show that it is possible to automatically segment calcified drusen from 3D SS-OCT scans by combining the OAC within drusen and the hypoTDs under drusen. We also propose a correction method for the segmentation of the retina pigment epithelium (RPE) overlying calcified drusen by automatically correcting the RPE by an amount of the OAC peak width along each A-line, leading to more accurate segmentation and quantification of drusen in general, and the calcified drusen in particular. A total of 29 eyes with nonexudative AMD and calcified drusen imaged with SS-OCT using the 6 x 6 mm2 scanning pattern were used in this study to test the performance of the proposed automated method. We demonstrated that the method achieved good agreement with the human expert graders in identifying the area of calcified drusen (Dice similarity coefficient: 68.27 +/- 11.09%, correlation coefficient of the area measurements: r = 0.9422, the mean bias of the area measurements = 0.04781 mm2).(c) 2023 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据