4.6 Article

Asymmetric parameter enhancement in the split-ring cavity array for virus-like particle sensing

期刊

BIOMEDICAL OPTICS EXPRESS
卷 14, 期 3, 页码 1216-1227

出版社

Optica Publishing Group
DOI: 10.1364/BOE.483831

关键词

-

向作者/读者索取更多资源

A novel virus detection method is proposed in this paper, which utilizes an indirect polarization parametric imaging method combined with a plasmonic split-ring nanocavity array coated with an Au film. A quantitative algorithm based on the extended Laplace operator is implemented. Experimental results show that the developed method has high detection sensitivity and can detect virus samples at low concentrations.
Quantitative detection of virus-like particles under a low concentration is of vital importance for early infection diagnosis and water pollution analysis. In this paper, a novel virus detection method is proposed using indirect polarization parametric imaging method combined with a plasmonic split-ring nanocavity array coated with an Au film and a quantitative algorithm is implemented based on the extended Laplace operator. The attachment of viruses to the split-ring cavity breaks the structural symmetry, and such asymmetry can be enhanced by depositing a thin gold film on the sample, which allows an asymmetrical plasmon mode with a large shift of resonance peak generated under transverse polarization. Correspondingly, the far-field scattering state distribution encoded by the attached virus exhibits a specific asymmetric pattern that is highly correlated to the structural feature of the virus. By utilizing the parametric image sins to collect information on the spatial photon state distribution and far-field asymmetry with a sub-wavelength resolution, the appearance of viruses can be detected. To further reduce the background noise and enhance the asymmetric signals, an extended Laplace operator method which divides the detection area into topological units and then calculates the asymmetric parameter is applied, enabling easier determination of virus appearance. Experimental results show that the developed method can provide a detection limit as low as 56 vp/150 mu L on a large scale, which has great potential in early virus screening and other applications.Published by Optica Publishing Group under the terms of the Creative Commons Attribution 4.0 License. Further distribution of this work must maintain attribution to the author(s) and the published article's title, journal citation, and DOI.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据