4.7 Article

Heat transfer analysis in artificial ground freezing for subway cross passage under seepage flow

期刊

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.tust.2022.104943

关键词

Subway cross passage; Artificial ground freezing; Seepage flow; Physical model test; Hydro -thermal coupling model

向作者/读者索取更多资源

In this study, a physical model test was conducted to investigate the freezing process under seepage conditions during subway cross passage construction. A hydro-thermal coupling model was derived to consider the variations of physical and thermodynamic parameters, and the numerical approach was validated by experimental results. The results showed that seepage velocity had the greatest effect on the thickness and shape of frozen body, while seepage temperature had the least impact.
Artificial ground freezing is an environmentally friendly and reliable method for ground improvement during subway cross passage construction under variable hydrological conditions. However, natural or induced seepage flow influences significantly the closure of frozen wall, as it supplies a substantial source of heat. In this study, a physical model test was conducted based on the freezing project of a subway cross passage in Beijing Subway Line 19. A series of thermistors were installed in some representative locations to measure the temperature distribution and further calculate power demand. Besides, a hydro-thermal coupling model of freezing process under seepage conditions was derived to consider the variations of physical and thermodynamic parameters of the porous media and the latent heat of ice/water phase transition. The numerical approach was validated by the experimental results. Furthermore, four crucial indicators affecting the closure time during AGF process were quantitatively evaluated. The results showed that the closure time at seepage velocities of 0, 25.6 and 51.2 m/ d were respectively 60, 110 and 441 min. Nevertheless, it was impossible to form continuous frozen bodies at 76.8 m/d. Among these indicators, the seepage velocity had the greatest effect on the thickness and shape of frozen body, while seepage temperature had the least impact.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据