4.1 Article

Analysis of thrombosis risk of commissural misaligned transcatheter aortic valve prostheses using particle image velocimetry

相关参考文献

注意:仅列出部分参考文献,下载原文获取全部文献信息。
Article Instruments & Instrumentation

Particle image velocimetry for flow analysis of the thrombogenic potential of transcatheter aortic valve prostheses

Finja Borowski et al.

Summary: Minimally invasive implantation of transcatheter aortic valve replacement (TAVR) has become the standard therapy for patients with severe aortic valve stenosis and increased surgical risk. Postoperative complications, such as subclinical leaflet thrombosis, cause long-term dysfunction of the TAVR, which may lead to patient death without revision therapy. Fluid mechanics mechanisms are associated with the assessment of thrombosis risk of TAVR.

TM-TECHNISCHES MESSEN (2022)

Review Cardiac & Cardiovascular Systems

Commissural alignment in transcatheter aortic valve replacement: A literature review

Abdul Muiz Khalid et al.

Summary: Transcatheter aortic valve replacement (TAVR) is a minimally invasive procedure used to replace a diseased aortic valve, but incomplete commissural alignment is a common issue. This review aims to evaluate the effectiveness of different techniques and procedures in achieving commissural alignment, and analyze their impact on coronary filling and re-access.

FRONTIERS IN CARDIOVASCULAR MEDICINE (2022)

Article Cardiac & Cardiovascular Systems

Self-expanding Transcatheter vs Surgical Aortic Valve Replacement in Intermediate-Risk Patients 5-Year Outcomes of the SURTAVI Randomized Clinical Trial

Nicolas M. Van Mieghem et al.

Summary: Among intermediate-risk patients with symptomatic severe aortic stenosis, major clinical outcomes at 5 years were similar for TAVR and surgery. TAVR was associated with superior hemodynamic valve performance but also with more paravalvular leak and valve reinterventions.

JAMA CARDIOLOGY (2022)

Article Engineering, Biomedical

In-Vitro Assessment of the Effects of Transcatheter Aortic Valve Leaflet Design on Neo-Sinus Geometry and Flow

Beatrice Ncho et al.

Summary: Shorter transcatheter aortic valve leaflet length is associated with reduced particle residence time and flow stagnation in the neo-sinus, potentially lowering the risk of leaflet thrombosis.

ANNALS OF BIOMEDICAL ENGINEERING (2021)

Article Cardiac & Cardiovascular Systems

Patient-Specific Implantation Technique to Obtain Neo-Commissural Alignment With Self-Expanding Transcatheter Aortic Valves

Gintautas Bieliauskas et al.

Summary: This study investigates a patient-specific implantation technique during TAVR to achieve safe and reproducible neo-commissural alignment of self-expanding transcatheter heart valves. The results suggest that this technique is feasible and safe in achieving optimal commissural alignment during TAVR procedures.

JACC-CARDIOVASCULAR INTERVENTIONS (2021)

Article Cardiac & Cardiovascular Systems

Sinus Hemodynamics After Transcatheter Aortic Valve in Transcatheter Aortic Valve

Hoda Hatoum et al.

ANNALS OF THORACIC SURGERY (2020)

Article Cardiac & Cardiovascular Systems

Coronary Access After TAVR

Tomoki Ochiai et al.

JACC-CARDIOVASCULAR INTERVENTIONS (2020)

Article Cardiac & Cardiovascular Systems

Incomplete expansion of transcatheter aortic valves is associated with propensity for valve thrombosis

Farhan Khodaee et al.

INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY (2020)

Article Multidisciplinary Sciences

Three-dimensional extent of flow stagnation in transcatheter heart valves

Vrishank Raghav et al.

JOURNAL OF THE ROYAL SOCIETY INTERFACE (2019)

Article Cardiac & Cardiovascular Systems

Impact of Leaflet Laceration on Transcatheter Aortic Valve-in-Valve Washout BASILICA to Solve Neosinus and Sinus Stasis

Hoda Hatoum et al.

JACC-CARDIOVASCULAR INTERVENTIONS (2019)

Article Cardiac & Cardiovascular Systems

Does transcatheter aortic valve alignment matter?

Jacob Andrew Salmonsmith et al.

OPEN HEART (2019)

Article Cardiac & Cardiovascular Systems

Implantation Depth and Rotational Orientation Effect on Valve-in-Valve Hemodynamics and Sinus Flow

Hoda Hatoum et al.

ANNALS OF THORACIC SURGERY (2018)

Article Cardiac & Cardiovascular Systems

Can bioprosthetic valve thrombosis be promoted by aortic root morphology? An in vitro study

Silje Ekroll Jahren et al.

INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY (2018)

Review Cardiac & Cardiovascular Systems

Computational Fluid Dynamics Assessment Associated with Transcatheter Heart Valve Prostheses: A Position Paper of the ISO Working Group

Zhenglun Alan Wei et al.

CARDIOVASCULAR ENGINEERING AND TECHNOLOGY (2018)

Article Engineering, Biomedical

The Effect of Valve-in-Valve Implantation Height on Sinus Flow

Prem A. Midha et al.

ANNALS OF BIOMEDICAL ENGINEERING (2017)

Article Medicine, General & Internal

Surgical or Transcatheter Aortic-Valve Replacement in Intermediate-Risk Patients

M. J. Reardon et al.

NEW ENGLAND JOURNAL OF MEDICINE (2017)

Article Cardiac & Cardiovascular Systems

Blood Stasis on Transcatheter Valve Leaflets and Implications for Valve-in-Valve Leaflet Thrombosis

Koohyar Vahidkhah et al.

ANNALS OF THORACIC SURGERY (2017)

Review Cardiac & Cardiovascular Systems

Durability of prostheses for transcatheter aortic valve implantation

Mani Arsalan et al.

NATURE REVIEWS CARDIOLOGY (2016)

Article Biophysics

Mechanical Platelet Activation Potential in Abdominal Aortic Aneurysms

Kirk B. Hansen et al.

JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME (2015)

Editorial Material Medicine, General & Internal

Reduced Leaflet Motion in Bioprosthetic Aortic Valves - The FDA Perspective

John C. Laschinger et al.

NEW ENGLAND JOURNAL OF MEDICINE (2015)

Review Medicine, Research & Experimental

The impact of blood shear rate on arterial thrombus formation

Kjell S. Sakariassen et al.

FUTURE SCIENCE OA (2015)

Article Instruments & Instrumentation

Using Micro-Particle-Image-Velocimetry for Measuring Velocities in a Coronary Vessel Treated by a Stent

Daniel Quosdorf et al.

TM-TECHNISCHES MESSEN (2011)

Article Medicine, General & Internal

Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery.

Martin B. Leon et al.

NEW ENGLAND JOURNAL OF MEDICINE (2010)

Article Cardiac & Cardiovascular Systems

Energy Loss Due to Paravalvular Leak With Transcatheter Aortic Valve Implantation

Ali N. Azadani et al.

ANNALS OF THORACIC SURGERY (2009)

Review Medicine, General & Internal

Mechanisms of thrombogenesis in atrial fibrillation: Virchow's triad revisited

Timothy Watson et al.

LANCET (2009)

Article Engineering, Biomedical

Fluid dynamic assessment of three polymeric heart valves using particle image velocimetry

Hwa Liang Leo et al.

ANNALS OF BIOMEDICAL ENGINEERING (2006)