4.7 Article

Development of receptor binding domain-based double-antigen sandwich lateral flow immunoassay for the detection and evaluation of SARS-CoV-2 neutralizing antibody in clinical sera samples compared with the conventional virus neutralization test

期刊

TALANTA
卷 255, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.talanta.2022.124200

关键词

SARS-CoV-2; Neutralizing antibodies (NAbs); Lateral flow immunoassay (LFIA); Double antigen sandwich (DAS); Receptor-binding domain (RBD)

向作者/读者索取更多资源

This study established fluorescent beads-based lateral flow immunoassay (FBs-LFIA) and latex beads-based LFIA (LBs-LFIA) methods to detect neutralizing antibodies (NAbs) in the serum of vaccinated people. The two LFIA methods showed good performance in clinical sample testing, with sensitivities of 97.44% and 98.29% and specificities of 98.28% and 97.70% compared to the conventional virus neutralization test (cVNT), respectively. LBs-LFIA was also suitable for whole blood sample testing, requiring only 3 μL of whole blood, allowing for at-home NAb detection.
Vaccination is an effective strategy to fight COVID-19. However, the effectiveness of the vaccine varies among different populations in varying immune effects. Neutralizing antibody (NAb) level is an important indicator to evaluate the protective effect of immune response after vaccination. Lateral flow immunoassay (LFIA) is a rapid, safe and sensitivity detection method, which has great potential in the detection of SARS-CoV-2 NAb. In this study, a fluorescent beads-based lateral flow immunoassay (FBs-LFIA) and a latex beads-based LFIA (LBs-LFIA) using double antigen sandwich (DAS) strategy were established to detect NAbs in the serum of vaccinated people. The limit of detection (LoD) of the FBs-LFIA was 1.13 ng mL- 1 and the LBs-LFIA was 7.11 ng mL- 1. The two LFIAs were no cross-reactive with sera infected by other pathogenic bacteria. Furthermore, the two LFIAs showed a good performance in testing clinical samples. The sensitivity of FBs-LFIA and LBs-LFIA were 97.44% (95%CI: 93.15%-99.18%) and 98.29% (95%CI: 95.84%-99.37%), and the specificity were 98.28% (95%CI: 95.37%- 99.45%) and 97.70% (95%CI: 94.82%-99.06%) compared with the conventional virus neutralization test (cVNT), respectively. Notably, the LBs-LFIA was also suitable for whole blood sample, requiring only 3 mu L of whole blood, which provided the possibility to detect NAbs at home. To sum up, the two LFIAs based on double antigen sandwich established by us can rapidly, safely, sensitively and accurately detect SARS-CoV-2 NAb in human serum.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据