4.0 Article

Investigation of BTEX removal efficiency using the electrolytic oxidation and Fenton's reaction

期刊

JOURNAL OF WATER CHEMISTRY AND TECHNOLOGY
卷 38, 期 3, 页码 149-157

出版社

PLEIADES PUBLISHING INC
DOI: 10.3103/S1063455X1603005X

关键词

BTEX; electrolytic oxidation; Fenton's reaction; produced water

资金

  1. Chinese Natural Science Foundation of China [51208299]
  2. Science & Technology Commission of Shanghai Municipality [11JC1408700]
  3. Shanghai Municipal Education Commission
  4. Shanghai Education Development Foundation [11CG52]

向作者/读者索取更多资源

The removal of benzene, toluene, ethyl benzene, and xylene (BTEX) using the electrolytic oxidation or Fenton's reaction has been studied. The value of current and pH value were shown to produce a significant effect on electrolytic oxidation of BTEX. More than 95% of BTEX could be removed at 500 mA current within 8 hours. In the case of Fenton's reaction it was established that more than 95% of BTEX could be removed at pH 4 with an addition of hydrogen peroxide in the amount of 12 mg/dm(3). The treatment cost based on electrolytic oxidation amounted to between $0.04 and $5.1 USD/m(3). For Fenton's reaction, the treatment cost was between $0.16 and $0.65/m(3). The costs of electrolytic oxidation and Fenton's reaction were similar to the cost of electrodialysis and cheaper than the freeze-thaw and evaporation; however, these costs were higher than for air flotation and the use of anoxic/aerobic granular activated carbon.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.0
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据