4.7 Article

Field measurement and evaluation of vibrations inside buildings above metro tunnels

期刊

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.soildyn.2023.107767

关键词

Metro tunnel; Buildings; Environmental vibration; Field measurement

向作者/读者索取更多资源

The development of buildings above metro tunnels in China has been rapid in recent years due to the utilization of land resources. However, these buildings are more susceptible to train-induced vibrations, which adversely affect the living quality of occupants. This study investigated the response characteristics of train-induced vibrations at the basement and floor slabs of buildings based on field-measured vibration data. The results showed that the vertical acceleration was greater than the horizontal acceleration, with the main frequency band of vertical vibration being 50-70 Hz.
The buildings above metro tunnels have developed rapidly in China in recent years because it can make comprehensive use of land resources. However, buildings are closer to the vibration source, which makes them sensitive to train-induced vibration and adversely affect the living quality of the building occupants. Based on field-measured vibration data of buildings above metro tunnels, the response characteristics of train-induced vibrations at the basement and floor slabs of buildings were investigated herein. The results showed that the vertical acceleration was much larger than the horizontal acceleration. The vertical acceleration of the floor slabs was greater than that of the basement, and the main frequency band of vertical vibration was 50-70 Hz. In this case, with an increase in the floor, the vertical acceleration of the buildings first increased, decayed rapidly, and finally increased slightly; that is, a vibration amplification phenomenon on the top three floors of the buildings was observed. The maximum vertical acceleration appeared on the 4th floor and the minimum vertical acceleration appeared on the floor, which was three floors below the top. The horizontal distance between the building and tunnel has a significant effect on the amplitude of vertical acceleration. The vibration levels caused by different trains have little difference, with a maximum variance of 2.3 dB. The Z vibration levels of all the measuring points were significantly lower than the first-level vibration limit (73 dB) specified in Chinese standard for limits and measurement methods of vibration in the room of residential building (GB/T 50355-2018).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据