In this study, a Ru(dcbpy)32+-functionalized gamma-CD-MOF was synthesized and used as an electrochemiluminescence (ECL) tag for the detection of CYFRA21-1, a biomarker of non-small cell lung cancer. The ECL tag exhibited favorable specificity, reliable accuracy, and remarkable stability, demonstrating the feasibility of using gamma-CD-based ECL tags for immunosensor construction and the potential for bioanalysis and clinical diagnosis of biomarkers.
Electrochemiluminescence (ECL)-functionalized metal-organic frameworks (MOFs) have become one of the most favored topics in biomarker immunoassays. Herein, a biocompatible tris(4,4 '-dicarboxylic acid-2,2 '-bipyridyl) ruthenium(II) [Ru(dcbpy)32+] functionalized gamma-cyclodextrin MOF was freshly prepared as an ECL tag for analyzing cytokeratin 19 fragment 21-1 (CYFRA21-1), a quintessential biomarker of non-small cell lung cancer. As a green ECL carrier, gamma-CD-MOF possessed a large cavity that can absorb enormous Ru(dcbpy)32+ molecules, obtaining consecutive stable ECL signals using N,N-dibutyl-2-hydroxyethylamine (DBAE) as a coreactant. Further func-tionalization of palladium nanoparticles with Ru@ gamma-CD-MOF not only facilitated the electron-transfer rate to boost the ECL emission but also immobilized the detection antibody (Ab2) via a Pd-N bond. To fabricate the sensing substrate, a porous NH2-MIL-125 (Ti) MOF was coated on the electrode to provide many binding sites for the capture antibody (Ab1). Through the traditional sandwich-type sensing format, the assembled immunosensor manifested a linear range with a limit of detection of 0.048 pg/mL (S/N = 3) within a concentration gradient of 0.0001-50 ng/mL for CYFRA21-1 detection. Given this strategy's merits of favorable specificity, reliable ac-curacy and remarkable stability, this study highlighted the feasibility of fabricating gamma-CD-based ECL tags for immunosensor construction, revealing this strategy's promising aptitude for bioanalysis and the clinical diag-nosis of biomarkers.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据