4.6 Article

Segmental Tissue Resistance of Healthy Young Adults during Four Hours of 6-Degree Head-Down-Tilt Positioning

期刊

SENSORS
卷 23, 期 5, 页码 -

出版社

MDPI
DOI: 10.3390/s23052793

关键词

bioimpedance; tissue resistance; segmental resistance; fluid-shifts; emulated microgravity; head-down-tilt

向作者/读者索取更多资源

This study evaluates the symmetry of fluid shifts in the human body under microgravity. The findings indicate that the fluid shifts induced by a 6-degree body tilt position result in similar changes in both left and right body segments. This has implications for the design of future wearable systems to monitor microgravity-induced fluid shifts.
(1) Background: One effect of microgravity on the human body is fluid redistribution due to the removal of the hydrostatic gravitational gradient. These fluid shifts are expected to be the source of severe medical risks and it is critical to advance methods to monitor them in real-time. One technique to monitor fluid shifts captures the electrical impedance of segmental tissues, but limited research is available to evaluate if fluid shifts in response to microgravity are symmetrical due to the bilateral symmetry of the body. This study aims to evaluate this fluid shift symmetry. (2) Methods: Segmental tissue resistance at 10 kHz and 100 kHz was collected at 30 min intervals from the left/right arm, leg, and trunk of 12 healthy adults over 4 h of 6 degrees head-down-tilt body positioning. (3) Results: Statistically significant increases were observed in the segmental leg resistances, first observed at 120 min and 90 min for 10 kHz and 100 kHz measurements, respectively. Median increases were approximately 11% to 12% for the 10 kHz resistance and 9% for the 100 kHz resistance. No statistically significant changes in the segmental arm or trunk resistance. Comparing the left and right segmental leg resistance, there were no statistically significant differences in the resistance changes based on the side of the body. (4) Conclusions: The fluid shifts induced by the 6 degrees body position resulted in similar changes in both left and right body segments (that had statistically significant changes in this work). These findings support that future wearable systems to monitor microgravity-induced fluid shifts may only require monitoring of one side of body segments (reducing the hardware needed for the system).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据