4.6 Article

Automated Multi-Wavelength Quality Assessment of Photoplethysmography Signals Using Modulation Spectrum Shape Features

相关参考文献

注意:仅列出部分参考文献,下载原文获取全部文献信息。
Article Chemistry, Analytical

Modulation Spectral Signal Representation for Quality Measurement and Enhancement of Wearable Device Data: A Technical Note

Abhishek Tiwari et al.

Summary: This passage introduces the background and applications of wearable devices, and proposes a signal processing representation. This representation can improve data quality, enhance the robustness of signal feature extraction, and be used for disease detection. The article provides an overview of multiple applications developed by the authors over the past decade, along with experimental results and comparisons with state-of-the-art benchmark methods. Open-source software is showcased, aiming to develop new applications. Finally, possible future research directions are discussed.

SENSORS (2022)

Article Chemistry, Analytical

Wrist Photoplethysmography Signal Quality Assessment for Reliable Heart Rate Estimate and Morphological Analysis

Serena Moscato et al.

Summary: This study aims to develop two classifiers to identify PPG pulses suitable for heart rate estimation and morphological analysis. By collecting wrist PPG data and using machine learning algorithms for analysis, better classification performance was achieved compared to other algorithms. This is important for improving the reliability of PPG parameters and broadening their applicability in real-world contexts.

SENSORS (2022)

Article Engineering, Biomedical

Optimized Signal Quality Assessment for Photoplethysmogram Signals Using Feature Selection

Fahimeh Mohagheghian et al.

Summary: This study proposes an approach to optimize the quality assessment of PPG signals. By using an ensemble-based feature selection scheme, the method achieves high accuracy in classifying PPG segments. The approach demonstrates robustness against dynamic variations and different physical activities, making it suitable for various wearable devices.

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING (2022)

Review Cardiac & Cardiovascular Systems

Smart wearable devices in cardiovascular care: where we are and how to move forward

Karim Bayoumy et al.

Summary: Technological innovations have penetrated deeply into our daily lives, with an emerging trend of utilizing commercial smart wearable devices for health management. The cardiovascular community must familiarize itself with wearable technologies and their clinical applications, but challenges such as device accuracy and standardized regulatory policies are hindering widespread adoption in clinical practice.

NATURE REVIEWS CARDIOLOGY (2021)

Review Engineering, Biomedical

Arrhythmia detection and classification using ECG and PPG techniques: a review

Neha et al.

Summary: ECG and PPG are non-invasive techniques that provide electrical and hemodynamic information of the heart, mainly for diagnosing cardiac abnormalities. Automatic detection techniques can help experts accurately identify the nature of arrhythmias.

PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE (2021)

Article Biophysics

Transfer learning from ECG to PPG for improved sleep staging from wrist-worn wearables

Qiao Li et al.

Summary: The study developed a sleep staging method using wrist-worn accelerometry and the photoplethysmogram (PPG) with transfer learning from a large electrocardiogram (ECG) database, resulting in improved accuracy and consistency. Results show that the combined PPG and actigraphy-based sleep stage classification approach has the potential for scalable application in large cross-sectional or longitudinal studies.

PHYSIOLOGICAL MEASUREMENT (2021)

Review Chemistry, Analytical

Sources of Inaccuracy in Photoplethysmography for Continuous Cardiovascular Monitoring

Jesse Fine et al.

Summary: Photoplethysmography (PPG) is a low-cost, noninvasive optical technique used for cardiovascular health and fitness monitoring, that can provide valuable clinical information beyond simple parameters like heart rate. Future PPG device development needs to consider sources of noise from individual differences, physiology, and external perturbations to be effective for health monitoring purposes.

BIOSENSORS-BASEL (2021)

Review Biology

Telehealth utilization during the Covid-19 pandemic: A systematic review

Salem Garfan et al.

Summary: During the COVID-19 pandemic, telehealth has been widely utilized due to its usability and safety in providing healthcare services. However, there are still challenges hindering the maximisation of telehealth, which requires further research and solutions.

COMPUTERS IN BIOLOGY AND MEDICINE (2021)

Proceedings Paper Engineering, Biomedical

Signal Quality Assessment of PPG Signals using STFT Time-Frequency Spectra and Deep Learning Approaches

Jianzhong Chen et al.

Summary: The deep learning network proposed for signal quality assessment in photoplethysmography achieves high accuracy of 98.3% with sensitivity, specificity, and F1-score of 98.9%, 96.7%, and 98.8% respectively. The heart rate error is significantly reduced after classification, making the approach useful in distinguishing good and bad PPG signals.

2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC) (2021)

Article Engineering, Biomedical

Heart rate estimation from wrist-type photoplethysmography signals during physical exercise

K. R. Arunkumar et al.

BIOMEDICAL SIGNAL PROCESSING AND CONTROL (2020)

Review Engineering, Biomedical

A review of machine learning techniques in photoplethysmography for the non-invasive cuff-less measurement of blood pressure

C. El-Hajj et al.

BIOMEDICAL SIGNAL PROCESSING AND CONTROL (2020)

Article Computer Science, Information Systems

A Supervised Approach to Robust Photoplethysmography Quality Assessment

Tania Pereira et al.

IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS (2020)

Article Multidisciplinary Sciences

Prediction of vascular aging based on smartphone acquired PPG signals

Lorenzo Dall'Olio et al.

SCIENTIFIC REPORTS (2020)

Review Medical Informatics

Quantified Self-Using Consumer Wearable Device: Predicting Physical and Mental Health

Bens Pardamean et al.

HEALTHCARE INFORMATICS RESEARCH (2020)

Article Engineering, Electrical & Electronic

A Wearable Sensor for Arterial Stiffness Monitoring Based on Machine Learning Algorithms

Fen Miao et al.

IEEE SENSORS JOURNAL (2019)

Article Biophysics

Evaluation of the signal quality of wrist-based photoplethysmography

Nikhilesh Pradhan et al.

PHYSIOLOGICAL MEASUREMENT (2019)

Article Mathematical & Computational Biology

Electroencephalography Amplitude Modulation Analysis for Automated Affective Tagging of Music Video Clips

Andrea Clerico et al.

Frontiers in Computational Neuroscience (2018)

Article Engineering, Biomedical

Spectro-Temporal Electrocardiogram Analysis for Noise-Robust Heart Rate and Heart Rate Variability Measurement

Diana P. Tobon et al.

IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE (2017)

Article Engineering, Biomedical

A time-frequency domain approach of heart rate estimation from photoplethysmographic (PPG) signal

Mohammad Tariqul Islam et al.

BIOMEDICAL SIGNAL PROCESSING AND CONTROL (2017)

Article Engineering, Biomedical

A Robust Heart Rate Monitoring Scheme Using Photoplethysmographic Signals Corrupted by Intense Motion Artifacts

Emroz Khan et al.

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING (2016)

Article Engineering, Biomedical

TROIKA: A General Framework for Heart Rate Monitoring Using Wrist-Type Photoplethysmographic Signals During Intensive Physical Exercise

Zhilin Zhang et al.

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING (2015)

Article Multidisciplinary Sciences

A new look at the essence of the imaging photoplethysmography

Alexei A. Kamshilin et al.

SCIENTIFIC REPORTS (2015)

Article Biophysics

Signal quality measures for pulse oximetry through waveform morphology analysis

J. Abdul Sukor et al.

PHYSIOLOGICAL MEASUREMENT (2011)

Proceedings Paper Engineering, Biomedical

Statistical Approach for the Detection of Motion/Noise Artifacts in Photoplethysmogram

Nandakumar Selvaraj et al.

2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC) (2011)

Article Computer Science, Artificial Intelligence

Feature selection based on mutual information: Criteria of max-dependency, max-relevance, and min-redundancy

HC Peng et al.

IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE (2005)

Review Critical Care Medicine

Statistics review 13: Receiver operating characteristic curves

V Bewick et al.

CRITICAL CARE (2004)