Fluorescence molecular tomography (FMT) is an optical imaging technology for visualizing the three-dimensional distribution of fluorescently labelled probes in vivo. Improving FMT reconstruction is challenging due to light scattering and ill-posed inverse problems. This study proposes a generalized conditional gradient method with adaptive regularization parameters (GCGM-ARP) to enhance FMT reconstruction performance. The GCGM-ARP method combines elastic-net (EN) regularization and adaptive adjustment of regularization parameters to achieve more accurate and robust reconstructions. Experimental results demonstrate that the GCGM-ARP method outperforms other reconstruction methods, exhibiting superior performance in source localization, dual-source resolution, morphology recovery, and robustness.
Fluorescence molecular tomography (FMT) is an optical imaging technology with the ability of visualizing the three-dimensional distribution of fluorescently labelled probes in vivo. However, due to the light scattering effect and ill-posed inverse problems, obtaining satisfactory FMT reconstruction is still a challenging problem. In this work, to improve the performance of FMT reconstruction, we proposed a generalized conditional gradient method with adaptive regularization parameters (GCGM-ARP). In order to make a tradeoff between the sparsity and shape preservation of the reconstruction source, and to maintain its robustness, elastic-net (EN) regularization is introduced. EN regularization combines the advantages of L-1-norm and L-2-norm, and overcomes the shortcomings of traditional L-p-norm regularization, such as over-sparsity, over-smoothness, and non-robustness. Thus, the equivalent optimization formulation of the original problem can be obtained. To further improve the performance of the reconstruction, the L-curve is adopted to adaptively adjust the regularization parameters. Then, the generalized conditional gradient method (GCGM) is used to split the minimization problem based on EN regularization into two simpler sub-problems, which are determining the direction of the gradient and the step size. These sub-problems are addressed efficiently to obtain more sparse solutions. To assess the performance of our proposed method, a series of numerical simulation experiments and in vivo experiments were implemented. The experimental results show that, compared with other mathematical reconstruction methods, GCGM-ARP method has the minimum location error (LE) and relative intensity error (RIE), and the maximum dice coefficient (Dice) in the case of different sources number or shape, or Gaussian noise of 5%-25%. This indicates that GCGM-ARP has superior reconstruction performance in source localization, dual-source resolution, morphology recovery, and robustness. In conclusion, the proposed GCGM-ARP is an effective and robust strategy for FMT reconstruction in biomedical application.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据