Individualized CT Angiography Protocols for the Evaluation of the Aorta: A Feasibility Study

期刊

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jvir.2016.01.009

关键词

-

资金

  1. Siemens (Forchheim, Germany)
  2. Philips (Best, The Netherlands)
  3. Bayer (Leverkusen, Germany)
  4. AGFA Healthcare (Rijswijk, The Netherlands)
  5. Siemens
  6. Bayer
  7. Philips

向作者/读者索取更多资源

Purpose: Ionizing radiation and iodinated contrast media are potential drawbacks to repetitive follow-up CT angiography in current practice. The aim of the present study was to optimize radiation dose and contrast agent volume by using individualized CT angiography protocols. Materials and Methods: Eighty consecutive patients referred for CT angiography of the whole aorta were prospectively evaluated. Patients were divided into groups of patients with a body mass index (BMI) < 28 kg/m(2) (group 1; n = 50) and those with a BMI >= 28 kg/m(2) (group 2; n = 30). A control group consisted of 50 consecutive patients who were retrospectively evaluated. CT angiography parameters on a second-generation dual-source scanner were 128 x 0.6-mm collimation, pitch of 0.9, rotation time of 0.33 seconds, tube voltages of 80/100/120 kVp (group 1/group 2/control), reference tube current of 400 mA, and image reconstruction at 1-mm/0.8-mm slice thickness (kernels, B30f [control] and I30f/strength 3 [groups 1/2]). The control group received 120 mL of contrast agent (300 mgI/mL) at 4.8 mL/s; groups 1 and 2 received 44 mL and 53 mL at 3.3 mL/s and 4 mL/s, respectively. Effective dose was evaluated for each patient. Image quality was determined by qualitative image analysis at the levels of the thoracic; abdominal, and pelvic aorta as nondiagnostic, diagnostic, good, or excellent, and quantitative image analysis was performed, including attenuation values and contrast-to-noise ratio (CNR). Results: Mean effective radiation dose values for CT angiography of the aorta were 3.7 mSv +/- 0.7 in group 1, 6.7 mSv +/- 1.4 in group 2, and 8.7 mSv +/- 1.9 in the control group (P < .001). Mean attenuation values and CNR levels were 334 HU +/- 66 and 16 8, respectively, in group 1, 277 HU 56 and 14 5 in group 2, and 305 HU 77 and 11 4 in the control group. Conclusions: Iterative reconstruction algorithms resulted in 23%-57% less radiation in combination with 55%-63% less contrast agent volume compared with standard CT protocols.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据