4.6 Article

New Trend in Toxicological Screening Using Volumetric Absorptive Microsampling (VAMS) and High-Resolution Mass Spectrometry (HR/MS) Combination

期刊

MOLECULES
卷 28, 期 8, 页码 -

出版社

MDPI
DOI: 10.3390/molecules28083466

关键词

toxicological screening; whole blood; volumetric absorptive microsampling (VAMS); Mitra (TM) device; high-resolution mass spectrometry; clinical application

向作者/读者索取更多资源

In toxicology, chromatographic methods coupled to HR/MS are commonly used for screenings, with the development of methods for alternative samples such as Volumetric Adsorptive Micro-Sampling. The optimized extraction procedure using Mitra (TM) allowed the confirmation of 87 compounds in spiked whole blood, with identification limits below 12.5 ng center dot mL(-1) for 82.2% of the investigated drugs. The novel screening approach showed a satisfying concordance in the analysis of poisoned patients' samples.
In toxicology, screenings are routinely performed using chromatographic methods coupled to detection systems such as high-resolution mass spectrometry (HR/MS). The increase in specificity and sensitivity of HRMS is responsible for the development of methods for alternative samples such as Volumetric Adsorptive Micro-Sampling. Whole blood overloaded with 90 drugs was sampled with 20 mu L Mitra (TM) to optimize the pre-analytical step as well as to determine the identification limits of drugs. Elution of chemicals was carried out in a solvent mixture through agitation and sonication. After dissolution, 10 mu L was injected into the chromatographic system coupled to the Orbitrap (TM) HR/MS. Compounds were confirmed against the laboratory library. The clinical feasibility was assessed in fifteen poisoned patients using the simultaneous sampling of plasma, whole blood and Mitra (TM). The optimized extraction procedure allowed us to confirm 87 compounds out of the 90 present in the spiked whole blood. Cannabis derivatives were not detected. For 82.2% of the investigated drugs, the identification limits were below 12.5 ng center dot mL(-1), with the extraction yields ranging from 80.6 to 108.7%. Regarding the patients' analysis, 98% of the compounds in plasma were detected in Mitra (TM) compared to whole blood, with a satisfying concordance (R-2 = 0.827). Our novel screening approach opens new insights into different toxicologic fields appropriate for pediatrics, forensics or to perform mass screening.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据