4.7 Review

Insight into continuous glucose monitoring: from medical basics to commercialized devices

相关参考文献

注意:仅列出部分参考文献,下载原文获取全部文献信息。
Article Materials Science, Multidisciplinary

Non-invasive and wearable glucose biosensor based on gel electrolyte for detection of human sweat

Nan Gao et al.

Summary: Flexible electrochemical biosensor based on graphene oxide and gold nanoparticle-modified screen-printed gold electrodes with gel electrolyte was proposed for accurate determination of glucose in human sweat, demonstrating promising potential for personal healthcare diagnosis. The biosensor showed stable sensing performance after 1000 bending cycles, and exhibited significant current response to glucose in the detection range of 1.25-850 μM and 0.85-7.72 mM, with a sensitivity of 53.7 and 27.4 μA/mM cm² and low detection limit (1.25 μM).

JOURNAL OF MATERIALS SCIENCE (2023)

Article Engineering, Environmental

Impact of Lactic Acid and Genipin Concentration on Physicochemical and Mechanical Properties of Chitosan Membranes

Izabela Kondratowicz et al.

Summary: Chitosan, a linear polysaccharide, is of great interest for biomedical applications. It is important to study the effect of additives on the properties of chitosan, and various material combinations can help enhance its performance.

JOURNAL OF POLYMERS AND THE ENVIRONMENT (2023)

Article Chemistry, Analytical

Investigation of GOx Stability in a Chitosan Matrix: Applications for Enzymatic Electrodes

Ayman Chmayssem et al.

Summary: In this study, a new biosensing membrane was designed for the development of an electrochemical glucose biosensor. The biosensor utilized a chitosan-based hydrogel that encapsulated glucose oxidase enzyme (GOx) and was crosslinked using glutaraldehyde. The stability of the biosensors was investigated under different storage conditions and it was found that they maintained stability for over six months in certain specific conditions. Catalase was also included to protect the biosensing membranes from enzymatic reaction by-products, thereby enhancing the lifetime of the biosensor.

SENSORS (2023)

Article Chemistry, Analytical

A Flexible Microfluidic Chip-Based Universal Fully Integrated Nanoelectronic System with Point-of-Care Raw Sweat, Tears, or Saliva Glucose Monitoring for Potential Noninvasive Glucose Management

Mimi Sun et al.

Summary: This article demonstrates a fully integrated nanoelectronic system that combines a flexible and disposable microfluidic enzymatic biosensor with a handheld wireless electronic device to monitor glucose in various raw noninvasive biofluids. The system shows potential utility in noninvasive glucose management for both healthy individuals and diabetic patients, and has the capability to expand to the monitoring of other biomolecules.

ANALYTICAL CHEMISTRY (2022)

Article Endocrinology & Metabolism

7. Diabetes Technology: Standards of Medical Care in Diabetes-2022

Summary: The American Diabetes Association (ADA) Standards of Medical Care in Diabetes provide clinical practice recommendations, treatment goals, and evaluation tools. The standards are updated by a professional committee and include a detailed introduction and evidence grading system.

DIABETES CARE (2022)

Article Endocrinology & Metabolism

Cost-effectiveness of second-line empagliflozin versus liraglutide for type 2 diabetes in the United States

Odette S. Reifsnider et al.

Summary: The study found that for patients with type 2 diabetes, the use of empagliflozin as second-line treatment after metformin is a dominant strategy for US payers, associated with lower lifetime costs, improved quality-adjusted life years, and reductions in cardiovascular death rates and complication rates in patients with cardiovascular diseases.

DIABETES OBESITY & METABOLISM (2022)

Article Endocrinology & Metabolism

Safety and Glycemic Outcomes During the MiniMed™ Advanced Hybrid Closed-Loop System Pivotal Trial in Adolescents and Adults with Type 1 Diabetes

Anders L. Carlson et al.

Summary: This trial assessed the safety and effectiveness of an advanced hybrid closed-loop system in adolescents and adults with type 1 diabetes. The results demonstrate that this system is safe and allows patients to achieve recommended glycemic targets, with the potential to further optimize glycemia.

DIABETES TECHNOLOGY & THERAPEUTICS (2022)

Article Endocrinology & Metabolism

Accuracy and Safety of Dexcom G7 Continuous Glucose Monitoring in Adults with Diabetes

Satish K. Garg et al.

Summary: The study evaluated the accuracy and safety of a seventh generation Dexcom CGM in adults with diabetes. Results showed single-digit MARD values with sensors placed on the arm or abdomen, indicating high accuracy.

DIABETES TECHNOLOGY & THERAPEUTICS (2022)

Review Endocrinology & Metabolism

Real-world evidence on clinical outcomes of people with type 1 diabetes using open-source and commercial automated insulin dosing systems: A systematic review

Christine Knoll et al.

Summary: This systematic review looked at the real-world evidence on commercial and open-source automated insulin dosing systems, finding that these systems can improve Time-in-Range and haemoglobin A(1c) with minimal concerns around severe hypoglycaemia.

DIABETIC MEDICINE (2022)

Article Chemistry, Analytical

Characterization of the Impact of Classical Cell-culture Media on the Response of Electrochemical Sensors

Ayman Chmayssem et al.

Summary: We propose a method to monitor cytotoxicity by measuring metabolites in real-time. The sensitivity of electrochemical sensors in different cell culture media is investigated, and it is found that the response of the sensors is significantly affected by FBS.

ELECTROANALYSIS (2022)

Article Endocrinology & Metabolism

Global accessibility of therapeutics for diabetes mellitus

Michael Fralick et al.

Summary: This paper discusses the differences and barriers in diabetes treatment and proposes potential solutions.

NATURE REVIEWS ENDOCRINOLOGY (2022)

Article Nutrition & Dietetics

What Is the Evidence That Dietary Macronutrient Composition Influences Exercise Performance? A Narrative Review

Timothy David Noakes

Summary: The introduction of the needle muscle biopsy technique in the 1960s revolutionized the study of muscle tissue in exercising humans. The role of muscle glycogen content and blood glucose concentration in fatigue during prolonged exercise is still a matter of debate.

NUTRIENTS (2022)

Review Medicine, Research & Experimental

Glucose biosensors in clinical practice: principles, limits and perspectives of currently used devices

Salvatore Andrea Pullano et al.

Summary: This review aims to present the importance of glucose monitoring devices and updated guidelines in managing diabetic patients. It discusses the technological and clinical advances in the field and proposes a roadmap for future development in glucose monitoring and patient management.

THERANOSTICS (2022)

Article Biochemistry & Molecular Biology

Biosensing human blood clotting factor by dual probes: Evaluation by deep long short-term memory networks in time series forecasting

Subash C. B. Gopinath et al.

Summary: This study utilized AIoT with deep long short-term memory networks for biosensing application to analyze the human blood clotting factor IX. The results showed a detection limit of 1 pM with the antibody as the probe, and 100 fM with the aptamer as the probe. The time-series predictions from the AIoT application supported the laboratory analyses results.

BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY (2022)

Review Chemistry, Multidisciplinary

Challenges and Strategies in Developing an Enzymatic Wearable Sweat Glucose Biosensor as a Practical Point-Of-Care Monitoring Tool for Type II Diabetes

Sook Mei Khor et al.

Summary: This review discusses the challenges and limitations of wearable biosensors for continuous sweat monitoring, particularly in the management of type II diabetes. It also proposes ten basic criteria for the development of a suitable, workable, and wearable sweat-based glucose biosensor. The insights provided in this review are important for the effective management and health monitoring of type II diabetes.

NANOMATERIALS (2022)

Article Primary Health Care

Hyperglycaemic and hypoglycaemic emergencies among patients with diabetes mellitus who participated in pilgrims of the 2019/1440H Hajj season

Abdulaziz Alfadhly et al.

Summary: This study aimed to explore the frequency and associated factors of diabetic emergencies among pilgrims with diabetes during Hajj. The study found that a considerable proportion of pilgrims with diabetes experienced diabetic emergencies, such as diabetic ketoacidosis, hyperosmolar hyperglycaemic state, and hypoglycaemia. Age, medication type, cardiovascular disease, and diabetes duration were identified as significant factors associated with these emergencies.

JOURNAL OF FAMILY MEDICINE AND PRIMARY CARE (2022)

Review Pharmacology & Pharmacy

Medical devices, smart drug delivery, wearables and technology for the treatment of Diabetes Mellitus

Daniel A. Domingo-Lopez et al.

Summary: This review discusses the recent technological advances in controlling and reversing Type 1 diabetes mellitus (T1DM), including glucose monitors, hormone delivery systems, control algorithms, and islet transplantation. These advancements aim to reduce hypo- and hyperglycaemic episodes and improve the effectiveness of treatment.

ADVANCED DRUG DELIVERY REVIEWS (2022)

Review Biophysics

Intelligent biosensing strategies for rapid detection in food safety: A review

Junjie Zhang et al.

Summary: With the advancements in technology, food safety testing has received increasing attention, and one prominent technology in this field is biosensors, due to their high sensitivity and specificity. By combining biosensor technology with emerging technologies like smartphones, 3D printing, artificial sensing, and the Internet of Things (IoT), biosensor technology has been further developed. The future of food detection requires intelligence, portability, and sensitivity. Based on these factors, this review highlights recent advancements in intelligence of biosensors and predicts their future applications.

BIOSENSORS & BIOELECTRONICS (2022)

Article Endocrinology & Metabolism

Alliance of Randomized Trials of Medicine vs Metabolic Surgery in Type 2 Diabetes (ARMMS-T2D): Study rationale, design, and methods

Donald C. Simonson et al.

Summary: ARMMS-T2D is a consortium of four randomized trials comparing metabolic surgery and medical/lifestyle therapy for long-term efficacy and safety in patients with diabetes. This study will provide important evidence for clinical decision-making.

DIABETES OBESITY & METABOLISM (2022)

Article Endocrinology & Metabolism

Comparison of MiniMed 780G system performance in users aged younger and older than 15 years: Evidence from 12 870 real-world users

Arcelia Arrieta et al.

Summary: This empirical study investigated the real-world glycaemic outcomes and goals achieved by users of the MiniMed 780G advanced hybrid closed loop system in different age groups of type 1 diabetes patients. The results show that both patients aged 15 years or younger and patients aged older than 15 years achieved good blood glucose control with the use of the AHCL system, in line with the international consensus recommendations.

DIABETES OBESITY & METABOLISM (2022)

Article Endocrinology & Metabolism

Glycemic outcomes of Advanced Hybrid Closed Loop system in children and adolescents with Type 1 Diabetes, previously treated with Multiple Daily Injections (MiniMed 780G system in T1D individuals, previously treated with MDI)

Goran Petrovski et al.

Summary: The study evaluated the glycemic outcomes in children and adolescents with Type 1 Diabetes (T1D) who were previously treated with Multiple Daily Injections (MDI) using a structured initiation protocol for the Advanced Hybrid Closed Loop (AHCL) Minimed 780G insulin pump system. The results showed that following a 10-day training, the participants achieved the internationally recommended goals of glycemic control with a time in range (TIR) above 70% and a HbA1c below 7%.

BMC ENDOCRINE DISORDERS (2022)

Article Environmental Sciences

Correlations of Salivary and Blood Glucose Levels among Six Saliva Collection Methods

Yangyang Cui et al.

Summary: This study demonstrated that unstimulated parotid salivary glucose level is the highest and most correlated with blood glucose level, accurately distinguishing DM patients. Additionally, the correlation between salivary glucose and blood glucose was relatively high and stable before breakfast.

INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH (2022)

Article Biotechnology & Applied Microbiology

What can AI-TENG do for Low Abundance Biosensing?

Min Jiang et al.

Summary: This article discusses the application of artificial intelligence and triboelectric nanogenerators in the development of biosensors. It focuses on the working principle of triboelectric nanogenerators and their combination with artificial intelligence. The article highlights the research work of AI-TENG in sensing biomolecules, organic compounds, and complex mixtures of cells. It concludes with a summary of the challenges and possible solutions in the application of AI-TENG to biosensors, as well as prospects for future development.

FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY (2022)

Article Endocrinology & Metabolism

Type 1 Diabetes (T1D) and Latent Autoimmune Diabetes in Adults (LADA): The Difference Between a Honeymoon and a Holiday

Livia M. R. Marcon et al.

Summary: Type 1 diabetes mellitus (T1D) is a chronic autoimmune disease that requires lifelong insulin replacement therapy. Young individuals with a genetic predisposition usually develop the disease after exposure to environmental triggers. Latent autoimmune diabetes of adults (LADA) is a subtype of autoimmune diabetes that occurs in adulthood and is characterized by milder beta-cell destruction and less intensive insulin treatment. Genetic predisposition for T1D is associated with an increased risk of other autoimmune diseases.

CASE REPORTS IN ENDOCRINOLOGY (2022)

Article Endocrinology & Metabolism

Application of the FreeStyle®Libre Glucose Monitoring System in type 1 diabetes mellitus patients aged 1-4 years

Yangshiyu Li et al.

Summary: The study investigated the accuracy, safety performance, and user satisfaction of the FreeStyle(R) Libre Glucose Monitoring System in children aged 4 months to 4 years with type 1 diabetes mellitus. The results showed that the system was accurate and safe for use in this age group, with varying levels of accuracy observed across different blood glucose levels.

PEDIATRIC DIABETES (2022)

Article Chemistry, Analytical

New Microfluidic System for Electrochemical Impedance Spectroscopy Assessment of Cell Culture Performance: Design and Development of New Electrode Material

Ayman Chmayssem et al.

Summary: This paper presents a modular EIS testing system based on patented technology for real-time and non-invasive monitoring of cell cultures, using easily processable methodologies and optimized electrode materials and design. The performance of the impedance spectroscopy devices was evaluated with human airway epithelial cell cultures, showing improved electrode performance and device functionality.

BIOSENSORS-BASEL (2022)

Article Chemistry, Analytical

Electrochemical Biosensing of Glucose Based on the Enzymatic Reduction of Glucose

Thomas Soranzo et al.

Summary: In this study, the enzyme aldehyde reductase was synthesized and cloned from a human gene. Spectrophotometric and electrochemical measurements demonstrated that aldehyde reductase can catalyze the reduction of glucose to sorbitol and significantly decrease the electrocatalytic oxidation current of NADPH after glucose addition. This work provides insights into the construction of an efficient electrochemical glucose biosensor.

SENSORS (2022)

Article Endocrinology & Metabolism

Global incidence, prevalence, and mortality of type 1 diabetes in 2021 with projection to 2040: a modelling study br

Gabriel A. Gregory et al.

Summary: This study developed a model based on available data to estimate the prevalence, incidence, associated mortality, and life expectancy of type 1 diabetes for 201 countries in 2021. The study also projected the prevalent cases in 2040. The burden of type 1 diabetes was found to be significant and expected to increase rapidly, particularly in resource-limited countries.

LANCET DIABETES & ENDOCRINOLOGY (2022)

Proceedings Paper Engineering, Biomedical

Machine Learning Classifiers for Noninvasive Glucose Detection Using A Single Wavelength Mid-infrared Photoacoustic Spectroscopy

Abdulrahman Aloraynan et al.

Summary: Machine learning is of great importance in noninvasive glucose detection, as it can improve the detection sensitivity and solve the complexity of detecting glucose. By developing different ML models and algorithms, accurate identification of glucose signals can be achieved even with variations in human skin properties.

BIOMEDICAL SPECTROSCOPY, MICROSCOPY, AND IMAGING II (2022)

Article Biochemistry & Molecular Biology

Clarke Error Grid Analysis for Performance Evaluation of Glucometers in a Tertiary Care Referral Hospital

Sohini Sengupta et al.

Summary: Glucometer plays a crucial role in monitoring blood glucose level, and accuracy is essential for optimal patient care. This study designed a quality assurance program for evaluating glucometers in a hospital, which showed compliance with ISO standards. The method used has been validated after one year and may serve as a prototype for glucometer quality management in a clinical setting.

INDIAN JOURNAL OF CLINICAL BIOCHEMISTRY (2022)

Editorial Material Endocrinology & Metabolism

Hybrid closed-loop therapy: Where are we in 2021?

Lalantha Leelarathna et al.

Summary: Hybrid closed-loop systems combine automated insulin delivery with manual boluses, offering improved glucose control and reduced risk of hypoglycaemia. Commercial systems like Medtronic 670G/780G, Tandem t:slim X2 Control IQ, and CamAPS FX have different features and benefits, catering to diverse needs and populations.

DIABETES OBESITY & METABOLISM (2021)

Article Endocrinology & Metabolism

Real-World Evidence and Glycemic Improvement Using Dexcom G6 Features

Halis Kaan Akturk et al.

Summary: The optional features of the G6 CGM system are widely adopted and users who engage more with alert and notification features tend to have better glycemic outcomes. Higher levels of interaction with CLARITY notifications are associated with higher time in range. Frequent use of the virtual assistant feature is linked to higher time in range and lower mean SGV.

DIABETES TECHNOLOGY & THERAPEUTICS (2021)

Article Multidisciplinary Sciences

Sensing the future of bio-informational engineering

Thomas A. Dixon et al.

Summary: Synthetic biology practices are now integrated into 'multiscale' designs, facilitating two-way communication between organic and inorganic information substrates in biological, digital, and cyber-physical system integrations. Novel applications of bio-informational engineering will emerge in environmental monitoring, precision agriculture, precision medicine, and next-generation biomanufacturing.

NATURE COMMUNICATIONS (2021)

Article Medical Informatics

Early Detection of Prediabetes and T2DM Using Wearable Sensors and Internet-of-Things-Based Monitoring Applications

Mirza Mansoor Baig et al.

Summary: This research focuses on early detection of prediabetes and T2DM using wearable technology and Internet-of-Things-based monitoring applications. An artificial intelligence model based on adaptive neuro-fuzzy inference was developed and achieved an overall agreement of 91% through testing and validation using Kappa analysis.

APPLIED CLINICAL INFORMATICS (2021)

Article Engineering, Biomedical

A fluorescence sandwich immunoassay for the real-time continuous detection of glucose and insulin in live animals

Mahla Poudineh et al.

Summary: The study demonstrates that multiple analytes can be continuously and simultaneously measured with picomolar sensitivity and sub-second resolution using a bead-based fluorescence sandwich immunoassay integrated with aptamers and antibodies in a custom microfluidic chip. The assay was used to quantify glucose and insulin concentrations in live diabetic rats, revealing differences in insulin pharmacokinetic responses between animals and different insulin formulations. The method can be easily adapted to monitor other blood analytes continuously and simultaneously in vivo.

NATURE BIOMEDICAL ENGINEERING (2021)

Article Endocrinology & Metabolism

Improved Glycemic Outcomes With Medtronic MiniMed Advanced Hybrid Closed-Loop Delivery: Results From a Randomized Crossover Trial Comparing Automated Insulin Delivery With Predictive Low Glucose Suspend in People With Type 1 Diabetes

Olivia J. Collyns et al.

Summary: The study found that the MiniMed Advanced Hybrid Closed-Loop (AHCL) system significantly improved glucose control in participants with type 1 diabetes, especially during the night. All age groups showed improvements, with adolescents showing the most significant improvement.

DIABETES CARE (2021)

Article Chemistry, Analytical

Nanohybrid electrocatalyst based on cobalt phthalocyanine-carbon nanotube-reduced graphene oxide for ultrasensitive detection of glucose in human saliva

Omotayo Adeniyi et al.

Summary: The current diabetes management systems rely on invasive blood sampling methods, but a non-invasive and painless saliva glucose measurement offers a desirable alternative for constant monitoring. The GCE-SWCNT/rGO/CoPc sensor, with its high sensitivity, stability, and selectivity, shows great potential for accurate and non-invasive glucose sensing in saliva. The sensor exhibits excellent sensitivity, specificity, storage stability, reusability, and fast response time for glucose detection.

SENSORS AND ACTUATORS B-CHEMICAL (2021)

Article Chemistry, Analytical

Plasmonic contact lens materials for glucose sensing in human tears

Won-Chul Lee et al.

Summary: The SERS-LM developed is capable of detecting glucose in human tears using a layer-by-layer structure composed of SF, AgNWs coated with MPBA, and PF. With a high density of hotspots for Raman signal enhancement, the SERS-LM demonstrates excellent glucose sensing performance within the concentration range of 500 nM - 1 mM. Furthermore, the tear glucose levels measured by the SERS-LM reflect trends of corresponding blood glucose levels, verifying its feasibility for noninvasive glucose sensing and potential application in various wearable personal health monitoring systems.

SENSORS AND ACTUATORS B-CHEMICAL (2021)

Article Biophysics

Integration of interstitial fluid extraction and glucose detection in one device for wearable non-invasive blood glucose sensors

Yao Yao et al.

Summary: The article introduces a simple two-electrode non-invasive blood glucose sensor, which extracts glucose concentration in ISF through RI process for blood glucose monitoring and validates its feasibility on different animals and human subjects.

BIOSENSORS & BIOELECTRONICS (2021)

Article Endocrinology & Metabolism

No more hypoglycaemia on days with physical activity and unrestricted diet when using a closed-loop system for 12 weeks: A post hoc secondary analysis of the multicentre, randomized controlled Diabeloop WP7 trial

Sylvia Franc et al.

Summary: The Diabeloop Generation-1 closed-loop system was effective in controlling hypoglycaemia induced by physical activity in patients with type 1 diabetes, by adjusting insulin delivery and recommending preventive carbohydrate intake. This study found that using the system helped avoid physical activity-induced hypoglycaemia in real-life conditions.

DIABETES OBESITY & METABOLISM (2021)

Article Health Care Sciences & Services

Diabetes care provided by national standards can improve patients' self-management skills: A qualitative study of how people with type 2 diabetes perceive primary diabetes care

Rebecka Husdal et al.

Summary: This qualitative study explored how individuals with type 2 diabetes perceive Swedish primary diabetes care and self-management support. Findings suggest that care provided according to national standards can enhance patients' self-management skills. Moreover, patients require support from healthcare staff and guidance on how to perform self-management activities.

HEALTH EXPECTATIONS (2021)

Article Endocrinology & Metabolism

The effects of professional continuous glucose monitoring as an adjuvant educational tool for improving glycemic control in patients with type 2 diabetes

Dulce Adelaida Rivera-Avila et al.

Summary: Professional continuous glucose monitoring has been shown to reduce HbA1c levels and improve glycemic control in patients with type 2 diabetes, with additional benefits seen in dietary patterns.

BMC ENDOCRINE DISORDERS (2021)

Review Endocrinology & Metabolism

β-Cell failure in diabetes: Common susceptibility and mechanisms shared between type 1 and type 2 diabetes

Hiroshi Ikegami et al.

Summary: Although diabetes mellitus is classified into different types based on etiology, there are shared susceptibilities and mechanisms in beta-cell failure among these subtypes. Understanding these common features can aid in the development of therapeutic strategies regardless of the type of diabetes. Future prospects in this area are also highlighted in the review.

JOURNAL OF DIABETES INVESTIGATION (2021)

Article Endocrinology & Metabolism

Cost Analysis of FreeStyle Libre(R) 2 System in Type 2 Diabetes Mellitus Population

Itziar Oyaguez et al.

Summary: The study compared the cost of FreeStyle Libre 2 system and self-monitoring of blood glucose in the T2DM population in Spain, demonstrating that using FreeStyle Libre 2 system for glucose monitoring can generate cost savings of up to 21.5% compared to SMBG.

DIABETES THERAPY (2021)

Article Chemistry, Analytical

Extended Noninvasive Glucose Monitoring in the Interstitial Fluid Using an Epidermal Biosensing Patch

Ernesto De la Paz et al.

Summary: A skin-worn, disposable, noninvasive glucose monitoring technology has been developed, enabling dynamic monitoring of glucose levels and addressing challenges of existing platforms.

ANALYTICAL CHEMISTRY (2021)

Article Endocrinology & Metabolism

Relationships between HbA1c and continuous glucose monitoring metrics of glycaemic control and glucose variability in a large cohort of children and adolescents with type 1 diabetes

Claudia Piona et al.

Summary: The study evaluated the relationships between HbA1c and CGM metrics in children/adolescents with Type 1 Diabetes (T1D), finding significant associations, particularly with %CV and LBGI. Different groups based on HbA1c and CGM metrics values showed varied but overlapping ranges. This highlights the importance of assessing CGM metrics independently of HbA1c value for understanding blood glucose control in pediatric T1D patients.

DIABETES RESEARCH AND CLINICAL PRACTICE (2021)

Article Endocrinology & Metabolism

American Association of Clinical Endocrinology Clinical Practice Guideline: The Use of Advanced Technology in the Management of Persons With Diabetes Mellitus

George Grunberger et al.

Summary: This article summarizes the evidence-based recommendations of AACE on the use of advanced technology in the management of diabetes, including 37 clinical practice recommendations informed by 357 citations. The study highlights that advanced diabetes technology can improve self-management capabilities and quality of life for patients, as well as enhance the efficiency and effectiveness of clinical decision-making.

ENDOCRINE PRACTICE (2021)

Article Medicine, General & Internal

Irisin is a predictor of sarcopenic obesity in type 2 diabetes mellitus A cross-sectional study

Ayten Oguz et al.

Summary: The study indicates that low irisin levels and poor glycemic control are independent risk factors for sarcopenia and sarcopenic obesity in patients with type 2 diabetes mellitus.

MEDICINE (2021)

Article Multidisciplinary Sciences

Perceived food palatability, blood glucose level and future discounting: Lack of evidence for blood glucose level's impact on reward discounting

Rafal Muda et al.

Summary: This study found that although blood glucose levels increased after consuming tasty food, it did not affect future discounting rates.

PLOS ONE (2021)

Review Chemistry, Analytical

Recent Advances in Enzymatic and Non-Enzymatic Electrochemical Glucose Sensing

Mohamed H. Hassan et al.

Summary: The detection of glucose plays a crucial role in diabetes management and various industries. The development of glucose sensors has greatly improved patient care and saved lives. Advanced approaches continue to be developed in order to enhance sensitivity, selectivity, and usability in both medical and industrial sectors.

SENSORS (2021)

Article Chemistry, Analytical

Development of a multiparametric (bio)sensing platform for continuous monitoring of stress metabolites

Ayman Chmayssem et al.

Summary: This paper presents the design and development of a multiparametric (bio) sensing platform for real-time monitoring of cell metabolites, highlighting its easy manufacturing process, easy scalability, modularity, versatility, and cost-effectiveness. The developed platform allows for multiparametric analysis of key factors indicating potential cell damage during cell culture. The proposal of a sensors platform based on thick-film coupled to microfluidic technology for accurate analysis of secreting stress metabolites during cell/tissues culture is also discussed.

TALANTA (2021)

Article Materials Science, Multidisciplinary

Highly sensitive and flexible pressure sensors using position- and dimension-controlled ZnO nanotube arrays grown on graphene films

Jun Beom Park et al.

Summary: A new technique for fabricating pressure sensors by hybridizing one-dimensional nanomaterials and two-dimensional graphene film has been developed. The sensors, based on vertically aligned ZnO nanotubes on graphene layers, demonstrate high pressure sensitivity and potential for wearable technology and advanced healthcare devices.Mechanical lift-off of hybrid structures allows for flexible, freestanding sensors with potential applications in monitoring breath and heart rate.

NPG ASIA MATERIALS (2021)

Review Chemistry, Multidisciplinary

The Impact of Recent Developments in Electrochemical POC Sensor for Blood Sugar Care

Wei Li et al.

Summary: This article discusses the development and advantages of electrochemical glucose sensors, the role of carbon materials such as graphene in sensors, and the limitations and challenges faced in future research.

FRONTIERS IN CHEMISTRY (2021)

Review Automation & Control Systems

Smart Contact Lenses for Biosensing Applications

Xin Ma et al.

Summary: Smart contact lenses with multifunctional biosensing capabilities and highly integrated performance provide a great platform for eye disease diagnosis and drug delivery. Biosensors in contact lenses measure key metabolites, and drug delivery through contact lenses can be beneficial.

ADVANCED INTELLIGENT SYSTEMS (2021)

Review Engineering, Electrical & Electronic

Recent Advances in Electrochemical Sensors for Wearable Sweat Monitoring: A Review

Kan Kan Yeung et al.

Summary: This review highlights the recent progress in the development and application of electrochemical sweat sensors and self-powered systems for wearable applications, including various types of sensors and novel functional nanomaterials. The advancement of battery-free wearable devices, such as self-powered biofuel cells and energy harvesting from novel materials, are also discussed, along with the challenges and opportunities in developing sweat sensor-based wearable systems for future directions.

IEEE SENSORS JOURNAL (2021)

Article Endocrinology & Metabolism

Professional continuous glucose monitoring and endocrinology eConsult for adults with type 2 diabetes in primary care: Results of a clinical pilot program

Kathryn L. Fantasia et al.

Summary: This study evaluated the feasibility and clinical outcomes of CGM-enhanced eConsult for patients with type 2 diabetes managed by primary care clinical pharmacists, compared to routine in-person endocrinology consultation. Results showed that CGM-enhanced eConsult provided more timely access to endocrinology expertise, was acceptable to patients, and yielded similar short-term glycemic outcomes. Further exploration of the effectiveness of CGM-enhanced eConsults is warranted.

JOURNAL OF CLINICAL AND TRANSLATIONAL ENDOCRINOLOGY (2021)

Article Ethics

Continuous Glucose Monitoring as a Matter of Justice

Steven R. Kraaijeveld

Summary: The development of continuous glucose monitoring (CGM) technology has greatly improved glycemic control for people with Type 1 diabetes (T1D), but unequal access to this technology due to cost limitations has resulted in unjust health inequalities and challenges in self-management for many individuals.

HEC FORUM (2021)

Review Physiology

Physiological mechanisms determining eccrine sweat composition

Lindsay B. Baker et al.

EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY (2020)

Article Multidisciplinary Sciences

A bioinspired analogous nerve towards artificial intelligence

Xinqin Liao et al.

NATURE COMMUNICATIONS (2020)

Article Medical Laboratory Technology

Basics and use of continuous glucose monitoring (CGM) in diabetes therapy

Guido Freckmann

JOURNAL OF LABORATORY MEDICINE (2020)

Article Gastroenterology & Hepatology

Causal relationships between NAFLD, T2D and obesity have implications for disease subphenotyping

Zhipeng Liu et al.

JOURNAL OF HEPATOLOGY (2020)

Article Chemistry, Analytical

Microfluidic Point-of-Care Devices: New Trends and Future Prospects for eHealth Diagnostics

Jorge Ricardo Mejia-Salazar et al.

SENSORS (2020)

Article Biophysics

Artificial intelligence biosensors: Challenges and prospects

Xiaofeng Jin et al.

BIOSENSORS & BIOELECTRONICS (2020)

Review Chemistry, Analytical

Microfluidics by Additive Manufacturing for Wearable Biosensors: A Review

Mahshid Padash et al.

SENSORS (2020)

Review Chemistry, Analytical

Recent advances and perspectives in sweat based wearable electrochemical sensors

A. M. Vinu Mohan et al.

TRAC-TRENDS IN ANALYTICAL CHEMISTRY (2020)

Review Endocrinology & Metabolism

Time in Range from Continuous Glucose Monitoring: A Novel Metric for Glycemic Control

Jee Hee Yoo et al.

DIABETES & METABOLISM JOURNAL (2020)

Review Endocrinology & Metabolism

Is an artificial pancreas (closed-loop system) for Type 1 diabetes effective?

C. K. Boughton et al.

DIABETIC MEDICINE (2019)

Article Endocrinology & Metabolism

Accuracy, Utilization, and Effectiveness Comparisons of Different Continuous Glucose Monitoring Systems

John B. Welsh et al.

DIABETES TECHNOLOGY & THERAPEUTICS (2019)

Review Biotechnology & Applied Microbiology

Wearable biosensors for healthcare monitoring

Jayoung Kim et al.

NATURE BIOTECHNOLOGY (2019)

Article Chemistry, Analytical

Electrocatalytic oxidation of glucose on bronze for monitoring of saliva glucose using a smart toothbrush

Jian Chen et al.

SENSORS AND ACTUATORS B-CHEMICAL (2019)

Review Chemistry, Multidisciplinary

Evolution of Wearable Devices with Real-Time Disease Monitoring for Personalized Healthcare

Kyeonghye Guk et al.

NANOMATERIALS (2019)

Review Endocrinology & Metabolism

A View Beyond HbA1c: Role of Continuous Glucose Monitoring

Haleh Chehregosha et al.

DIABETES THERAPY (2019)

Review Chemistry, Physical

Immobilized Enzymes in Biosensor Applications

Hoang Hiep Nguyen et al.

MATERIALS (2019)

Article Endocrinology & Metabolism

A case of immune-mediated type 1 diabetes mellitus due to congenital rubella infection

Huseyin Anil Korkmaz et al.

ANNALS OF PEDIATRIC ENDOCRINOLOGY & METABOLISM (2019)

Article Endocrinology & Metabolism

Economic Costs of Diabetes in the US in 2017

Wenya Yang et al.

DIABETES CARE (2018)

Article Endocrinology & Metabolism

A Prospective Multicenter Evaluation of the Accuracy of a Novel Implanted Continuous Glucose Sensor: PRECISE II

Mark P. Christiansen et al.

DIABETES TECHNOLOGY & THERAPEUTICS (2018)

Review Pharmacology & Pharmacy

A review of implantable biosensors for closed-loop glucose control and other drug delivery applications

Kee Scholten et al.

INTERNATIONAL JOURNAL OF PHARMACEUTICS (2018)

Review Chemistry, Analytical

Wearable non-invasive epidermal glucose sensors: A review

Jayoung Kim et al.

TALANTA (2018)

Article Multidisciplinary Sciences

Simultaneous lancet-free monitoring of alcohol and glucose from low-volumes of perspired human sweat

Ashlesha Bhide et al.

SCIENTIFIC REPORTS (2018)

Article Chemistry, Multidisciplinary

From Point-of-Care Testing to eHealth Diagnostic Devices (eDiagnostics)

Dionysios C. Christodouleas et al.

ACS CENTRAL SCIENCE (2018)

Article Endocrinology & Metabolism

Could FreeStyle Libre sensor glucose data support decisions for safe driving?

G. Rayman et al.

DIABETIC MEDICINE (2018)

Review Chemistry, Analytical

In Vivo Chemical Sensors: Role of Biocompatibility on Performance and Utility

Robert J. Soto et al.

ANALYTICAL CHEMISTRY (2017)

Article Chemistry, Multidisciplinary

Calibration-Free Electrochemical Biosensors Supporting Accurate Molecular Measurements Directly in Undiluted Whole Blood

Hui Li et al.

JOURNAL OF THE AMERICAN CHEMICAL SOCIETY (2017)

Review Chemistry, Analytical

Glucose Sensing for Diabetes Monitoring: Recent Developments

Danielle Bruen et al.

SENSORS (2017)

Article Chemistry, Analytical

Lancet-free and label-free diagnostics of glucose in sweat using Zinc Oxide based flexible bioelectronics

Rujuta D. Munje et al.

SENSORS AND ACTUATORS B-CHEMICAL (2017)

Article Biochemistry & Molecular Biology

Glucose biosensor based on immobilization of glucose oxidase on a carbon paste electrode modified with microsphere-attached L-glycine

Soner Donmez et al.

BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY (2017)

Review Endocrinology & Metabolism

Continuous glucose monitoring: A review of the technology and clinical use

David C. Klonoff et al.

DIABETES RESEARCH AND CLINICAL PRACTICE (2017)

Article Endocrinology & Metabolism

Accuracy of a Fourth-Generation Subcutaneous Continuous Glucose Sensor

Mark P. Christiansen et al.

DIABETES TECHNOLOGY & THERAPEUTICS (2017)

Review Endocrinology & Metabolism

Continuous Glucose Monitoring: A Review of Recent Studies Demonstrating Improved Glycemic Outcomes

David Rodbard

DIABETES TECHNOLOGY & THERAPEUTICS (2017)

Article Endocrinology & Metabolism

Clinical Use of Continuous Glucose Monitoring in Adults with Type 2 Diabetes

Anders L. Carlson et al.

DIABETES TECHNOLOGY & THERAPEUTICS (2017)

Article Endocrinology & Metabolism

Factory-Calibrated Continuous Glucose Sensors: The Science Behind the Technology

Udo Hoss et al.

DIABETES TECHNOLOGY & THERAPEUTICS (2017)

Article Medicine, Legal

The usefulness of point-of-care (POC) tests in screening elevated glucose and ketone body levels postmortem

Anna-Mari Walta et al.

FORENSIC SCIENCE INTERNATIONAL (2016)

Review Food Science & Technology

Recent developments in blood glucose sensors

Hui-Chen Wang et al.

JOURNAL OF FOOD AND DRUG ANALYSIS (2015)

Review Endocrinology & Metabolism

Glycemic Variability: How Do We Measure It and Why Is It Important?

Sunghwan Suh et al.

DIABETES & METABOLISM JOURNAL (2015)

Review Chemistry, Analytical

Approaches Toward Allowing Electroanalytical Devices to be Used in Biological Fluids

Abbas Barfidokht et al.

ELECTROANALYSIS (2014)

Article Chemistry, Analytical

Evaluation of Some Redox Mediators in the Design of Reagentless Amperometric Glucose Biosensor

Asta Kausaite-Minkstimiene et al.

ELECTROANALYSIS (2014)

Review Endocrinology & Metabolism

Adipokines - removing road blocks to obesity and diabetes therapy

Matthias Blueher

MOLECULAR METABOLISM (2014)

Article Endocrinology & Metabolism

Performance of the Medtronic Sentrino continuous glucose management (CGM) system in the cardiac intensive care unit

Mikhail Kosiborod et al.

BMJ OPEN DIABETES RESEARCH & CARE (2014)

Article Biochemical Research Methods

Small electron-transfer proteins as mediators in enzymatic electrochemical biosensors

Celia M. Silveira et al.

ANALYTICAL AND BIOANALYTICAL CHEMISTRY (2013)

Article Physics, Applied

Scalable, non-invasive glucose sensor based on boronic acid functionalized carbon nanotube transistors

Mitchell B. Lerner et al.

APPLIED PHYSICS LETTERS (2013)

Review Engineering, Biomedical

Towards Smart Tattoos: Implantable Biosensors for Continuous Glucose Monitoring

Yun Jung Heo et al.

ADVANCED HEALTHCARE MATERIALS (2013)

Article Engineering, Electrical & Electronic

A 3-μW CMOS Glucose Sensor for Wireless Contact-Lens Tear Glucose Monitoring

Yu-Te Liao et al.

IEEE JOURNAL OF SOLID-STATE CIRCUITS (2012)

Article Engineering, Biomedical

Electroconductive Polymers in (Bio)chemical Sensors

Dorota G. Pijanowska et al.

BIOCYBERNETICS AND BIOMEDICAL ENGINEERING (2011)

Article Computer Science, Information Systems

An internet of things-based personal device for diabetes therapy management in ambient assisted living (AAL)

Antonio J. Jara et al.

PERSONAL AND UBIQUITOUS COMPUTING (2011)

Review Chemistry, Analytical

Glucose Biosensors: An Overview of Use in Clinical Practice

Eun-Hyung Yoo et al.

SENSORS (2010)

Review Medical Laboratory Technology

Overview on self-monitoring of blood glucose

Martina Montagnana et al.

CLINICA CHIMICA ACTA (2009)

Article Endocrinology & Metabolism

A Tale of Two Compartments: Interstitial Versus Blood Glucose Monitoring

Eda Cengiz et al.

DIABETES TECHNOLOGY & THERAPEUTICS (2009)

Article Biotechnology & Applied Microbiology

Salivary Glucose Concentration and Excretion in Normal and Diabetic Subjects

Cedric Jurysta et al.

JOURNAL OF BIOMEDICINE AND BIOTECHNOLOGY (2009)

Review Chemistry, Multidisciplinary

Electrochemical glucose biosensors

Joseph Wang

CHEMICAL REVIEWS (2008)

Review Biochemical Research Methods

Ferrocene-based derivatization in analytical chemistry

Bettina Seiwert et al.

ANALYTICAL AND BIOANALYTICAL CHEMISTRY (2008)

Article Chemistry, Analytical

Ruthenium purple-mediated microelectrode biosensors based on sol-gel film

Faming Tian et al.

ANALYTICAL CHEMISTRY (2007)

Article Biotechnology & Applied Microbiology

Glucose oxidase immobilization on a novel cellulose acetate-polymethylmethacrylate membrane

S Rauf et al.

JOURNAL OF BIOTECHNOLOGY (2006)

Review Endocrinology & Metabolism

Continuous glucose monitoring and closed-loop systems

R Hovorka

DIABETIC MEDICINE (2006)

Review Biochemical Research Methods

A glucose-sensing contact lens: from bench top to patient

R Badugu et al.

CURRENT OPINION IN BIOTECHNOLOGY (2005)