4.5 Article

Prostate perfusion mapping using Fourier-transform based velocity-selective arterial spin labeling: Choice of cutoff velocity and comparison with brain

相关参考文献

注意:仅列出部分参考文献,下载原文获取全部文献信息。
Article Radiology, Nuclear Medicine & Medical Imaging

Evaluation of 3D stack-of- spiral turbo FLASH acquisitions for pseudo-continuous and velocity-selective ASL-derived brain perfusion mapping

Dan Zhu et al.

Summary: This study compared the performance of 3D SOS-TFL and 3D GRASE for ASL at 3T and found that 3D SOS-TFL can achieve similar results with fewer shots and higher temporal resolution. It also has minimal relaxation-induced blurring and reduced CSF contamination, making it especially suitable for VSASL.

MAGNETIC RESONANCE IN MEDICINE (2023)

Article Neurosciences

Test-retest reliability of 3D velocity-selective arterial spin labeling for detecting normal variations of cerebral blood flow

Feng Xu et al.

Summary: This MRI study evaluated the test-retest reliability of VSI-prepared 3D VSASL protocol to measure baseline CBF variations in different brain regions among cognitively normal participants. The study found that both absolute and relative CBF showed higher variability, but could still detect normal variations using VSASL.

NEUROIMAGE (2023)

Article Oncology

Cancer statistics, 2022

Rebecca L. Siegel et al.

Summary: Each year, the American Cancer Society compiles data on cancer occurrence and outcomes in the United States. The latest data shows that breast and prostate cancer progress has stagnated, while lung cancer has shown improvements in survival rates. Lung cancer incidence for advanced disease has declined while localized-stage rates have increased, resulting in higher survival rates. Mortality patterns align with incidence trends, with lung cancer deaths declining rapidly, breast cancer deaths slowing, and prostate cancer deaths stabilizing.

CA-A CANCER JOURNAL FOR CLINICIANS (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

Perfusion measurement in brain gliomas using velocity-selective arterial spin labeling: comparison with pseudo-continuous arterial spin labeling and dynamic susceptibility contrast MRI

Yaoming Qu et al.

Summary: The performance of velocity-selective (VS) ASL was evaluated in patients with untreated gliomas, compared with both pseudo-continuous (PC) ASL and dynamic susceptibility contrast-enhanced perfusion-weighted imaging (DSC-PWI). VSASL showed comparable results with DSC-PWI in visual inspection and yielded higher correlation with DSC-PWI in quantitative analysis compared to PCASL. VSASL also showed superior diagnostic sensitivity, specificity, and accuracy in glioma grading compared to PCASL.

EUROPEAN RADIOLOGY (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

A revisit of the k-space filtering effects of magnetization-prepared 3D FLASH and balanced SSFP acquisitions: Analytical characterization of the point spread functions

Dan Zhu et al.

Summary: In this study, the magnetization-prepared 3D FLASH and balanced SSFP imaging in MRI were analyzed using point spread functions (PSF). The results showed that the slope of the PSF can characterize the relative contrast between different magnetization preparation levels, while the intercept of the PSF may lead to quantification bias in imaging. In addition, FLASH and bSSFP imaging have very little blurring effect compared to conventional fast spin echo (FSE). The study also provided analytical selections of sequence parameters to optimize relative contrast-to-noise ratio (ruCNR).

MAGNETIC RESONANCE IMAGING (2022)

Review Radiology, Nuclear Medicine & Medical Imaging

Velocity-selective arterial spin labeling perfusion MRI: A review of the state of the art and recommendations for clinical implementation

Qin Qin et al.

Summary: This review article provides an overview of the current status of velocity-selective arterial spin labeling (VSASL) perfusion MRI and discusses its concepts, implementation, clinical applications, and technical challenges.

MAGNETIC RESONANCE IN MEDICINE (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

Multi-organ comparison of flow-based arterial spin labeling techniques: Spatially non-selective labeling for cerebral and renal perfusion imaging

Suzanne L. Franklin et al.

Summary: Flow-based ASL techniques provide an alternative to spatially selective techniques with similar performance in the brain and comparable performance in the kidney, with VSI-ASL showing the most potential in brain imaging. Further improvements are needed in kidney imaging to match FAIR's performance.

MAGNETIC RESONANCE IN MEDICINE (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Ensuring both velocity and spatial responses robust to B0/B1+ field inhomogeneities for velocity-selective arterial spin labeling through dynamic phase-cycling

Dapeng Liu et al.

Summary: The study evaluated the velocity and spatial responses of velocity-selective arterial spin labeling under different field inhomogeneities, proposing a dynamic phase-cycling approach that showed considerable improvements over existing schemes. This approach demonstrated robustness in both velocity and spatial responses across a wide range of B-0 and B-1(+) field inhomogeneities through numerical simulations, phantom scans, and brain perfusion measurements.

MAGNETIC RESONANCE IN MEDICINE (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Multi-Parametric Evaluation of Cerebral Hemodynamics in Neonatal Piglets Using Non-Contrast-Enhanced Magnetic Resonance Imaging Methods

Dapeng Liu et al.

Summary: This study utilized various MRI techniques to quantitatively measure cerebral hemodynamic parameters in neonatal piglets, demonstrating the feasibility of these techniques in assessing CBF, OEF, and CMRO2. The results indicate that non-contrast MRI can be used to measure cerebral hemodynamic parameters in normal and brain-injured piglets.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Three-dimensional whole-brain mapping of cerebral blood volume and venous cerebral blood volume using Fourier transform-based velocity-selective pulse trains

Wenbo Li et al.

Summary: The study developed 3D MR1 methods for CBV and vCBV estimation with whole-brain coverage using FT-VS pulse trains, demonstrating high correlation between CBV and vCBV values in gray and white matter, and comparable results to existing literature.

MAGNETIC RESONANCE IN MEDICINE (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Magnetic resonance angiography and perfusion mapping by arterial spin labeling using Fourier transform-based velocity-selective pulse trains: Examination on a commercial perfusion phantom

Feng Xu et al.

Summary: The study evaluated FT velocity-selective saturation-based VSMRA and FT velocity-selective inversion-based VSASL on a commercial perfusion phantom. Results showed the dependence of VSMRA and VSASL on velocity-encoding directions, with careful selection recommended for applications in various organs.

MAGNETIC RESONANCE IN MEDICINE (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Arterial spin labelling as a gadolinium-free alternative in the detection of prostate cancer

M. Boschheidgen et al.

Summary: The study aimed to evaluate the performance of Gadolinium-free arterial spin labelling (ASL) sequences as a non-invasive imaging method for prostate cancer and compare it to conventional DCE MRI. Results showed that ASL had significantly higher contrast ratios in differentiating prostate cancer from benign tissue, and was relatively accurate in detecting prostate cancer.

MAGNETIC RESONANCE IMAGING (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Ensuring both velocity and spatial responses robust to B-0/B-1(+) field inhomogeneities for velocity-selective arterial spin labeling through dynamic phase-cycling

Dapeng Liu et al.

Summary: The study aimed to evaluate the velocity and spatial responses of velocity-selective arterial spin labeling under different field inhomogeneities. Numerical simulations and human scans showed that the dynamic phase-cycling approach significantly improved the labeling efficiency and control module performance under nonuniform field conditions.

MAGNETIC RESONANCE IN MEDICINE (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Three-dimensional whole -brain mapping of cerebral blood volume and venous cerebral blood volume using Fourier transform based velocity -selective pulse trains

Wenbo Li et al.

Summary: In this study, 3D MR1 methods were developed for cerebral blood volume (CBV) and venous cerebral blood volume (vCBV) estimation with whole-brain coverage using Fourier transform based velocity-selective (FT-VS) pulse trains. Results showed high correlation of CBV and vCBV values in gray and white matter in different brain regions among healthy volunteers. The feasibility of FT-VS-based CBV and vCBV estimation for 3D acquisition with large spatial coverage was demonstrated.

MAGNETIC RESONANCE IN MEDICINE (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Non-contrast-enhanced abdominal MRA at 3 T using velocity-selective pulse trains

Dan Zhu et al.

MAGNETIC RESONANCE IN MEDICINE (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Improved velocity-selective labeling pulses for myocardial ASL

Vanessa Landes et al.

MAGNETIC RESONANCE IN MEDICINE (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Improved velocity-selective-inversion arterial spin labeling for cerebral blood flow mapping with 3D acquisition

Dapeng Liu et al.

MAGNETIC RESONANCE IN MEDICINE (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Cerebral blood volume mapping using Fourier-transform-based velocity-selective saturation pulse trains

Qin Qin et al.

MAGNETIC RESONANCE IN MEDICINE (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

Whole-brain arteriography and venography: Using improved velocity-selective saturation pulse trains

Wenbo Li et al.

MAGNETIC RESONANCE IN MEDICINE (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

Characterization and suppression of stripe artifact in velocity-selective magnetization-prepared unenhanced MR angiography

Taehoon Shin et al.

MAGNETIC RESONANCE IN MEDICINE (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

Fast Measurement of Blood T1 in the Human Carotid Artery at 3T: Accuracy, Precision, and Reproducibility

Wenbo Li et al.

MAGNETIC RESONANCE IN MEDICINE (2017)

Article Radiology, Nuclear Medicine & Medical Imaging

Quantitative measurement of cerebral blood volume using velocity-selective pulse trains

Dexiang Liu et al.

MAGNETIC RESONANCE IN MEDICINE (2017)

Article Radiology, Nuclear Medicine & Medical Imaging

Identification and Reduction of Image Artifacts in Non-Contrast-Enhanced Velocity-Selective Peripheral Angiography at 3T

Taehoon Shin et al.

MAGNETIC RESONANCE IN MEDICINE (2016)

Article Radiology, Nuclear Medicine & Medical Imaging

Velocity-selective magnetization-prepared non-contrast-enhanced cerebral MR angiography at 3 Tesla: Improved immunity to B0/B1 inhomogeneity

Qin Qin et al.

MAGNETIC RESONANCE IN MEDICINE (2016)

Article Radiology, Nuclear Medicine & Medical Imaging

Velocity-Selective-Inversion Prepared Arterial Spin Labeling

Qin Qin et al.

MAGNETIC RESONANCE IN MEDICINE (2016)

Article Biophysics

Feasibility of measuring prostate perfusion with arterial spin labeling

Xiufeng Li et al.

NMR IN BIOMEDICINE (2013)

Article Radiology, Nuclear Medicine & Medical Imaging

Overview of Dynamic Contrast-Enhanced MRI in Prostate Cancer Diagnosis and Management

Sadhna Verma et al.

AMERICAN JOURNAL OF ROENTGENOLOGY (2012)

Review Urology & Nephrology

Angiogenesis in prostate cancer: onset, progression and imaging

Giovanna Russo et al.

BJU INTERNATIONAL (2012)

Article Biochemical Research Methods

NIH Image to ImageJ: 25 years of image analysis

Caroline A. Schneider et al.

NATURE METHODS (2012)

Article Radiology, Nuclear Medicine & Medical Imaging

Advancements in MR Imaging of the Prostate: From Diagnosis to Interventions

David Bonekamp et al.

RADIOGRAPHICS (2011)

Article Radiology, Nuclear Medicine & Medical Imaging

Continuous Flow-Driven Inversion for Arterial Spin Labeling Using Pulsed Radio Frequency and Gradient Fields

Weiying Dai et al.

MAGNETIC RESONANCE IN MEDICINE (2008)

Article Radiology, Nuclear Medicine & Medical Imaging

Velocity-selective arterial spin labeling

Eric C. Wong et al.

MAGNETIC RESONANCE IN MEDICINE (2006)

Article Oncology

Microvessel density in prostate carcinoma

AV Bono et al.

PROSTATE CANCER AND PROSTATIC DISEASES (2002)