4.2 Article

Association between Bioimpedance Spectroscopy and Magnetic Resonance Lymphangiography in the Diagnosis and Assessment of Lymphedema

期刊

出版社

THIEME MEDICAL PUBL INC
DOI: 10.1055/a-2102-0261

关键词

MR lymphangiography; bioimpedance spectroscopy; lymphedema; diagnostic imaging; lymphedema staging

类别

向作者/读者索取更多资源

This study examines the relationship between bioimpedance spectroscopy (BIS) and magnetic resonance lymphangiography (MRL) in the staging and assessment of lymphedema. The results show that L-Dex scores have high sensitivity, specificity, and positive predictive value for detecting MRL-identified lymphedema. However, L-Dex scores have difficulty distinguishing between adjacent severity levels of lymphedema and a high false negative rate.
Background This study assesses associations between bioimpedance spectroscopy (BIS) and magnetic resonance lymphangiography (MRL) in the staging and assessment of lymphedema.Methods Adults who received MRL and BIS between 2020 and 2022 were included. We collected fluid, fat, and lymphedema severity ratings, and measured fluid stripe thickness, subcutaneous fat width, and lymphatic diameter on MRL. BIS lymphedema index (L-Dex) scores were collected from patient charts. We assessed sensitivity and specificity of L-Dex scores to detect MRL-identified lymphedema, and examined associations between L-Dex scores and MRL imaging measures.Results Forty-eight limbs across 40 patients were included. L-Dex scores had 72.5% sensitivity and 87.5% specificity for detecting MRL-defined lymphedema, with a 96.7% estimated positive predictive value and 38.9% negative predictive value. L-Dex scores were associated with MRL fluid and fat content scores ( p & LE; 0.05), and lymphedema severity ( p = 0.01), with better discrimination between fluid than fat content levels on pairwise analysis, and poor discrimination between adjacent severity levels. L-Dex scores were correlated with distal and proximal limb fluid stripe thickness (distal: rho = 0.57, p < 0.01; proximal: rho = 0.58, p < 0.01), partially correlated with distal subcutaneous fat thickness when accounting for body mass index (rho = 0.34, p = 0.02), and were not correlated with lymphatic diameter ( p = 0.25).Conclusion L-Dex scores have high sensitivity, specificity, and positive predictive value for the identification of MRL-detected lymphedema. L-Dex has difficulty distinguishing between adjacent severity levels of lymphedema and a high false negative rate, explained in part by reduced discrimination between levels of fat accumulation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据