4.6 Article

Are homografts superior to conventional prosthetic valves in the setting of infective endocarditis involving the aortic valve?

期刊

JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY
卷 151, 期 5, 页码 1239-1246

出版社

MOSBY-ELSEVIER
DOI: 10.1016/j.jtcvs.2015.12.061

关键词

Infective endocarditis; surgery; valve replacement; homograft; prognosis

资金

  1. American Association for Thoracic Surgery (AATS)

向作者/读者索取更多资源

Background: Surgical dogma suggests that homografts should be used preferentially, compared with conventional xenograft or mechanical prostheses, in the setting of infective endocarditis (IE), because they have greater resistance to infection. However, comparative data that support this notion are limited. Methods: From the prospective databases of 2 tertiary academic centers, we identified 304 consecutive adult patients (age >= 17 years) who underwent surgery for active IE involving the aortic valve (AV), in the period 2002 to 2014. Short-and long-term outcomes were evaluated using propensity scores and inverse-probability weighting to adjust for selection bias. Results: Homografts, and xenograft and mechanical prostheses, were used in 86 (28.3%), 139 (45.7%), and 79 (26.0%) patients, respectively. Homografts were more often used in the setting of prosthetic valve endocarditis (58.1% vs 28.8%, P = .002) and methicillin-resistant Staphylococcus (25.6% vs 12.1%, P = .002), compared with conventional prostheses. Early mortality occurred in 17 (19.8%) in the homograft group, and 20 (9.2%) in the conventional group (P = .019). During follow-up (median: 29.4 months; interquartile-range: 4.7-72.6 months), 60 (19.7%) patients died, and 23 (7.7%) experienced reinfection, with no significant differences in survival (P = .23) or freedom from reinfection rates (P = .65) according to the types of prostheses implanted. After adjustments for baseline characteristics, using propensity-score analyses, use of a homograft did not significantly affect early death (odds ratio 1.61; 95% confidence interval [CI], 0.73-3.40, P = .23), overall death (hazard ratio 1.10; 95% CI, 0.62-1.94, P = .75), or reinfection (hazard ratio 1.04; 95% CI, 0.49-2.18, P = .93). Conclusions: No significant benefit to use of homografts was demonstrable with regard to resistance to reinfection in the setting of IE. The choice among prosthetic options should be based on technical and patient-specific factors. Lack of availability of homografts should not impede appropriate surgical intervention.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据