4.7 Article

The Clinical Suitability of an Artificial Intelligence-Enabled Pain Assessment Tool for Use in Infants: Feasibility and Usability Evaluation Study

期刊

出版社

JMIR PUBLICATIONS, INC
DOI: 10.2196/41992

关键词

pain assessment; clinical utility; sensitivity; specificity; immunization; accuracy; precision; PainChek Infant; infant; newborn; baby; babies; pain; facial; artificial intelligence; machine learning; model; detection; assessment

向作者/读者索取更多资源

PainChek Infant, a mobile health-based pain assessment tool, shows high feasibility and accuracy in assessing and monitoring pain in infants. It provides a reliable and convenient solution for evaluating infant pain, which is critical for effective management.
Background: Infants are unable to self-report their pain, which, therefore, often goes underrecognized and undertreated. Adequate assessment of pain, including procedural pain, which has short- and long-term consequences, is critical for its management. The introduction of mobile health-based (mHealth) pain assessment tools could address current challenges and is an area requiring further research. Objective: The purpose of this study is to evaluate the accuracy and feasibility aspects of PainChek Infant and, therefore, assess its applicability in the intended setting. Methods: By observing infants just before, during, and after immunization, we evaluated the accuracy and precision at different cutoff scores of PainChek Infant, which is a point-of-care mHealth-based solution that uses artificial intelligence to detect pain and intensity based solely on facial expression. We used receiver operator characteristic analysis to assess interpretability and establish a cutoff score. Clinician comprehensibility was evaluated using a standardized questionnaire. Other feasibility aspects were evaluated based on comparison with currently available observational pain assessment tools for use in infants with procedural pain. Results: Both PainChek Infant Standard and Adaptive modes demonstrated high accuracy (area under the curve 0.964 and 0.966, respectively). At a cutoff score of >= 2, accuracy and precision were 0.908 and 0.912 for Standard and 0.912 and 0.897 for Adaptive modes, respectively. Currently available data allowed evaluation of 16 of the 17 feasibility aspects, with only the cost of the outcome measurement instrument unable to be evaluated since it is yet to be determined. PainChek Infant performed well across feasibility aspects, including interpretability (cutoff score defined), ease of administration, completion time (3 seconds), and clinician comprehensibility. Conclusions: This work provides information on the feasibility of using PainChek Infant in clinical practice for procedural pain assessment and monitoring, and demonstrates the accuracy and precision of the tool at the defined cutoff score.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据