4.5 Article

Image-based digital post-discharge surveillance in England: measuring patient enrolment, engagement, clinician response times, surgical site infection, and carbon footprint

期刊

JOURNAL OF HOSPITAL INFECTION
卷 133, 期 -, 页码 15-22

出版社

W B SAUNDERS CO LTD
DOI: 10.1016/j.jhin.2023.01.001

关键词

Surgical site infection; Carbon emissions; Surveillance; Smartphone; Photograph

向作者/读者索取更多资源

Using patient smartphones for post-discharge surveillance is an effective method for collecting patient data, including response rates, infection rates, clinician response time and carbon emissions. It has a positive impact on patient engagement and success in continuous monitoring.
Background: Surgical site infections (SSIs) can have a significant impact on patients, their families and healthcare providers. With shortening inpatient periods, the post-discharge element of surveillance is becoming increasingly important. Proactive surveillance, including digital wound images using patient smartphones, may be an efficient alternative to traditional methods for collecting post-discharge surveillance (PDS).Aim: To determine success in patient enrolment and engagement including reasons for non-response, the time for clinicians to respond to patients, SSI rates, and carbon emis-sions when conducting PDS using patient smartphones.Methods: An evaluation was undertaken for a one-month period (June 2022) in two adult cardiac surgery services which routinely used patient smartphones for PDS, using the secure Islacare (Isla) system. Findings: The initial patient response rate for Isla was 87.3%, and the majority of patients (73%) remained engaged throughout the 30-day period. There was no significant difference in age, gender, operation type or distance to hospital between Isla responders or non-responders, or if the hospital provided a photo at discharge or not. Patients using Isla had a shorter post-discharge stay (P 1/4 0.03), although this was not attributed to the platform. Patients not owning a smartphone and a technical issue were the main barriers to participation. Overall, nine SSIs were recorded, eight through the Isla surveillance and one through a hospital transfer readmission. The carbon emission associated with the SSI ranged from 5 to 2615 kg CO2e.Conclusion: In a real-world setting, using patient smartphones is an effective method to collect PDS, including wound images.(c) 2023 The Author(s). Published by Elsevier Ltd on behalf of The Healthcare Infection Society. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据