4.4 Article

External Validation of the Tor Vergata 3D Printed Models of the Upper Urinary Tract and Stones for High-Fidelity Simulation of Retrograde Intrarenal Surgery

期刊

JOURNAL OF ENDOUROLOGY
卷 37, 期 5, 页码 607-614

出版社

MARY ANN LIEBERT, INC
DOI: 10.1089/end.2022.0847

关键词

3D; anatomy; RIRS; simulation; training; validation

向作者/读者索取更多资源

This study validates the effectiveness of 3D printed models of the upper urinary tract and synthetic training stones for high-fidelity simulation of retrograde intrarenal surgery (RIRS). The results support the usage of these models in simulation courses and evaluate their potential role in standardized training curricula.
Introduction: Novel training modalities are being investigated to overcome the challenges associated with learning retrograde intrarenal surgery (RIRS). Consequently, a series of 3D printed models of the upper urinary tract and stones designed for ex vivo surgical simulation was introduced in 2021. This study aims to provide external validation of the training model and assess its role in the development of surgical skills.Materials and Methods: A mixed cohort of 20 urologists at different levels of expertise participated in a whole-day live simulation event to examine the model and perform a timed simulation of intrarenal navigation, stone relocation, and laser fragmentation. Operative times were recorded and two independent expert endourologists scored the simulations according to a modified Objective Structured Assessment of Technical Skills (OSATS) scale. Five novice urologists from the cohort performed three further simulations in a subsequent event to assess improvement in surgical skills.Results: Face validity was demonstrated with a median score of >= 4/5 in each of the 11 items investigated. Content validity was also effectively reached, with 100% positive impressions with regard to the usefulness for the acquisition of surgical skills. Significant differences were observed among operative times stratified per surgeon experience (all p < 0.0050), thus providing construct validity. Median total OSATS score for novices was 14 (range 8, 25) and was found to be significantly different from expected expert performance (p = 0.0010). Repeated simulations by novices led to a progressive reduction of operative times (p = 0.0313) and increase in median total OSATS (p = 0.0625).Conclusion: The 3D printed models of upper urinary tract and synthetic training stones for the high-fidelity simulation of each phase of RIRS were validated by this study. The results encourage the usage of the models in simulation courses and the evaluation of their potential role in standardized training curricula.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据