4.6 Article

Mean 16-Year Results of Total Hip Arthroplasty With Alumina Ceramic Femoral Heads on Highly Cross-Linked Polyethylene in Patients 50 Years or Less

期刊

JOURNAL OF ARTHROPLASTY
卷 38, 期 7, 页码 S346-S350

出版社

CHURCHILL LIVINGSTONE INC MEDICAL PUBLISHERS
DOI: 10.1016/j.arth.2023.04.041

关键词

highly cross-linked polyethylene; primary total hip arthroplasty; young patient; ceramic; wear

向作者/读者索取更多资源

This study retrospectively investigated the long-term outcomes of total hip arthroplasty using highly cross-linked polyethylene (HXLPE) with alumina ceramic bearings. The results showed excellent wear properties, patient-reported outcomes, and acceptable survivorships at an average 16-year follow-up.
Background: Highly cross-linked polyethylene (HXLPE) is a widely used bearing surface in total hip arthroplasty (THA); long-term results in young patients are limited. We previously demonstrated excellent results in HXPLE on cobalt-chrome femoral heads at 15-year mean follow-up. The purpose of the present study was to investigate polyethylene wear rates, implant survivorships, wear-related revisions, and patient-reported outcomes (PROs) in a young patient cohort who had alumina ceramic on HXPLE coupling at an average 16-year follow-up. Methods: This was a retrospective study of 128 hips that underwent THA with HXLPE on alumina ceramic bearings between March 1, 2004, and April 15, 2007. The patient's mean age was 38 years (range, 13 to 50). All THAs utilized HXPLE liners with alumina ceramic heads. The University of California, Los Angeles activity score and modified Harris hip scores were collected preoperatively and at each follow-up. Martell hip analysis suite was used for wear calculations. Results: At average 16 years (range, 13 to 18), aseptic revision survivorship was 93.3% and osteolysis/wear survivorship was 99.2%. The mean linear wear rate was 0.0191 mm/year and mean volumetric wear rate was 19.43 mm(3)/y, both of which were clinically undetectable. We observed excellent PROs with a significant increase in mean modified Harris hip scores (43.6 to 87.4, P <.0001) and the University of California, Los Angeles activity scores (4.0 to 6.0, P <.0001). There were no statistically significant differences in PROs or wear rates between ceramic and cobalt-chrome groups. Conclusion: At a mean 16-year follow-up, young patients who had HXLPE on ceramic coupling had excellent wear properties, PROs, and acceptable survivorships. (c) 2023 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据