4.6 Article

A varying-swirl design concept for dry powder inhalers

期刊

JOURNAL OF AEROSOL SCIENCE
卷 171, 期 -, 页码 -

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.jaerosci.2023.106162

关键词

Dry powder inhaler; Swirling flow; in-vitro deposition; Particle image velocimetry; Computational fluid dynamics; Particle tracking

向作者/读者索取更多资源

A novel design concept for a dry powder inhaler is proposed to improve its aerosol performance and achieve higher lung deposition. The design includes a varying inner cross-section of the device, resulting in improved flow characteristics and an increased fine particle fraction. This design concept was further adapted with the use of a honeycomb grid, which showed a reduction in fine particle fraction when placed after the tangential inlets but had no significant effect on throat deposition when placed at the mouthpiece exit.
The de-agglomeration potential of a dry powder inhaler (DPI) strongly affects its aerosol performance. Typically, a swirling flow is employed for the entrainment and de-agglomeration of drug powder into the inhalation air flow. Here, we propose a novel design concept that passively modifies the DPI swirling-flow, and thereby the de-agglomeration process, in order to achieve higher lung deposition. The essence of this design is a varying inner cross-section of the pipe-shaped device, realised in the form of converging and diverging circular sections placed after the tangential inlets in the device. An improved aerosol performance was shown for this device, with the fine particle fraction reaching 68.4% of the emitted dose, compared with 66.8% from that of the baseline device. This was found to be a direct effect of the modified flow characteristics generated within the device and thereafter emerging from its mouthpiece. These flow characteristics were determined from computational fluid dynamics simulations and particle image velocimetry measurements.Adaptations of this DPI design concept were achieved through the use of a honeycomb grid placed either after the device tangential inlets, or at the device mouthpiece exit. When placed after the inlets, a 10.4% reduction in the fine particle fraction was observed, as the air flow was straightened due to the influence of the grid which significantly reduced the flow-swirl before the flow entered the converging-diverging sections. Whereas, when placed at the mouthpiece exit, the flow-straightening effect of the grid resulted in reduced lateral spreading of the emitted aerosol but did not significantly affect throat deposition.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据