4.7 Article

Fault Detection and Classification to Design a Protection Scheme for Utility Grid with High Penetration of Wind and Solar Energy

期刊

出版社

WILEY-HINDAWI
DOI: 10.1155/2023/4418741

关键词

-

向作者/读者索取更多资源

This paper presents a protection scheme for utility grid with high share of renewable energy, using Stockwell transform, Hilbert transform, and alienation coefficient for feature extraction. The scheme is effective in identifying faults in various scenarios and discriminates fault events from operational events. The proposed hybrid protection method outperforms the alienation coefficient-based protection scheme reported in literature in terms of fault detection accuracy and noise tolerance. The performance evaluation shows that the proposed method has significantly lower error rates compared to the existing scheme.
This paper designed a protection scheme for utility grid with high share of renewable energy (RE) generated from wind energy and solar energy plants. This is based on extraction of features from the current using Stockwell transform (ST), Hilbert transform (HT), and alienation coefficient. A Stockwell index (SI) is designed by extracting current features using ST, a Hilbert index (HI) is designed by extracting current features using HT, and an alienation index (AI) is designed by extracting current features using an alienation coefficient. A fault index (FI) is formulated by multiplying the SI, HI, AI, and WF (weight factor). This FI is implemented for fault detection. Fault classification is achieved considering number of fault phases and ground fault index (GFI). This GFI is designed by processing zero sequence currents applying ST. GFI effectively identifies the ground involved during event of a fault. A designed protection scheme is effective to identify faults in the scenario of high RE share and during various cases of study which includes the variations of fault impedance, different fault occurrence angles (FOA), fault incident at different nodes, and noisy condition. This protection scheme effectively discriminates the fault events from the operational events such as feeder operation, load, and capacitor switching. Performance of hybrid protection method formulated in this paper is better relative to alienation coefficient-based protection scheme (ACPS) reported in literature. The ACPS has maximum error and mean error of fault detection equal to 9.54% and 5.99%, respectively, which is relatively high compared to the respective values for the proposed method which are 1.89% and 0.978%, respectively. ACPS is effective for detecting the fault events in noise level of 30 dB SNR (signal-to-noise ratio) whereas the proposed method effectively identifies the faults in the high noise scenario of 20 dB SNR.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据