4.2 Article

Medium-term outcomes of conventional versus short uncemented femoral stems for primary total hip arthroplasty in patients younger than 55 years

期刊

HIP INTERNATIONAL
卷 -, 期 -, 页码 -

出版社

SAGE PUBLICATIONS LTD
DOI: 10.1177/11207000231177588

关键词

Complications; conventional stem; outcomes; short stem; survival rates; total hip arthroplasty; young patients

向作者/读者索取更多资源

This study compares the outcomes and survival of two different approaches for hip replacement in young patients. Both approaches, involving different types of stem, showed good implant survival rates and functional outcomes at a medium-term follow-up. However, complications and radiolucent lines were more frequent with the collarless conventional-length stem.
Background: Short stems are designed with a bone preservation philosophy in mind. This study aims to compare the outcomes/complications and survival of a collarless fully hydroxyapatite (HA)-coated conventional tapered stem and a HA-coated partial neck-retaining uncemented short stem in patients <= 55 years old at medium-term follow-up. Methods: We retrospectively studied 247 uncemented THAs operated between 2010 and 2014, comparing 146 patients treated with the fully HA-coated collarless stem (Group A) with 101 patients treated with a partial neck preserving, HA-coated short stem (Group B). 87 and 62 males were in groups A and B, respectively (p = 0.11). The mean age of the series was 46 years (17-55) (p =0.16). The mean follow-up of groups A and B were 9.9 (7-12) years and 9.7 (7-12) years, respectively (p =0.21). Results: Mean Harris Hip Score improved from 55 to 92 in group A (p <0.001) and from 54 to 95 in group B (p <0.001), without differences between groups. Mean femoral neck length preservation in groups A and B was 13.6 (0-28) mm and 26 (11-38) mm, respectively (p =0.001). 13 (8.9%) and 1 (1%) patients in groups A and B presented postoperative complications, respectively (p =0.008). The conventional stem group had more aseptic loosening (Group A 3.4% vs. Group B 0%, p =0.06) along with more Symptomatic radiolucent lines (Group A 3.4% vs. Group B 0%, p =0.06). Conclusions: Both conventional and short stems showed excellent implant survival rates and functional outcomes at a mean follow-up of 9.8 years. However, complications and radiolucent lines were more frequent with a collarless conventional-length stem. Bone preservation of the femoral neck and diaphysis may be preferred in active young patients.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据