4.5 Article

Vertebropexy as a semi-rigid ligamentous alternative to lumbar spinal fusion

期刊

EUROPEAN SPINE JOURNAL
卷 32, 期 5, 页码 1695-1703

出版社

SPRINGER
DOI: 10.1007/s00586-023-07647-y

关键词

Vertebropexy; Ligamentous stabilization; Spinal stabilization; Semi-rigid; Lumbar fusion; Lumbar spine

向作者/读者索取更多资源

The purpose of this study was to develop ligamentous vertebral stabilization techniques that can be used after microsurgical decompression and midline decompression, and to elaborate their biomechanical characteristics. The results showed that vertebral stabilization significantly reduced the range of motion, especially in flexion-extension.
PurposeTo develop ligamentous vertebral stabilization techniques (vertebropexy) that can be used after microsurgical decompression (intact posterior structures) and midline decompression (removed posterior structures) and to elaborate their biomechanical characteristics.MethodsFifteen spinal segments were biomechanically tested in a stepwise surgical decompression and ligamentous stabilization study. Stabilization was achieved with a gracilis or semitendinosus tendon allograft, which was attached to the spinous process (interspinous vertebropexy) or the laminae (interlaminar vertebropexy) in form of a loop. The specimens were tested (1) in the native state, after (2) microsurgical decompression, (3) interspinous vertebropexy, (4) midline decompression, and (5) interlaminar vertebropexy. In the intact state and after every surgical step, the segments were loaded in flexion-extension (FE), lateral shear (LS), lateral bending (LB), anterior shear (AS) and axial rotation (AR).ResultsInterspinous vertebropexy significantly reduced the range of motion (ROM) in all loading scenarios compared to microsurgical decompression: in FE by 70% (p < 0.001), in LS by 22% (p < 0.001), in LB by 8% (p < 0.001) in AS by 12% (p < 0.01) and in AR by 9% (p < 0.001). Interlaminar vertebropexy decreased ROM compared to midline decompression by 70% (p < 0.001) in FE, 18% (p < 0.001) in LS, 11% (p < 0.01) in LB, 7% (p < 0.01) in AS, and 4% (p < 0.01) in AR. Vertebral segment ROM was significantly smaller with the interspinous vertebropexy compared to the interlaminar vertebropexy for all loading scenarios except FE. Both techniques were able to reduce vertebral body segment ROM in FE, LS and LB beyond the native state.ConclusionVertebropexy is a new concept of semi-rigid spinal stabilization based on ligamentous reinforcement of the spinal segment. It is able to reduce motion, especially in flexion-extension. Studies are needed to evaluate its clinical application.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据