4.5 Article

Reverse encoding distortion correction for diffusion-weighted MRI: Efficacy for improving image quality and ADC evaluation for differentiating malignant from benign areas in suspected prostatic cancer patients

期刊

EUROPEAN JOURNAL OF RADIOLOGY
卷 162, 期 -, 页码 -

出版社

ELSEVIER IRELAND LTD
DOI: 10.1016/j.ejrad.2023.110764

关键词

MRI; Prostate; Prostate cancer; Diffusion weighted imaging; Apparent diffusion coefficient

向作者/读者索取更多资源

The purpose of this study was to determine the influence of reverse encoding distortion correction (RDC) on ADC measurement and its efficacy for improving image quality and diagnostic performance for differentiating malignant from benign prostatic areas on prostatic DWI. The results showed that RDC DWI had significantly better SNR and overall image quality compared to DWI. ROC analysis also demonstrated that the diagnostic performance of ADC in RDC DWI was better than in DWI. Therefore, RDC technique has the potential to improve image quality and ability to differentiate malignant from benign prostatic areas on DWIs.
Purpose: The purpose of this study was to determine the influence of reverse encoding distortion correction (RDC) on ADC measurement and its efficacy for improving image quality and diagnostic performance for differentiating malignant from benign prostatic areas on prostatic DWI. Methods: Forty suspected prostatic cancer patients underwent DWI with or without RDC (i.e. RDC DWI or DWI) using a 3 T MR system as well as pathological examinations. The pathological examination results indicated 86 areas were malignant while 86 out of 394 areas were computationally selected as benign. SNR for benign areas and muscle and ADCs for malignant and benign areas were determined by ROI measurements on each DWI. Moreover, overall image quality was assessed with a 5-point visual scoring system on each DWI. Paired t-test or Wilcoxon's signed rank test was performed to compare SNR and overall image quality for DWIs. ROC analysis was then used to compare the diagnostic performance, and sensitivity (SE), specificity (SP) and accuracy (AC) of ADC were compared between two DWI by means of McNemar's test. Results: SNR and overall image quality of RDC DWI showed significant improvements when compared with those of DWI (p < 0.05). Areas under the curve (AUC), SP and AC of DWI RDC DWI (AUC: 0.85, SP: 72.1%, AC: 79.1%) were significantly better than those of DWI (AUC: 0.79, p = 0.008; SP: 64%, p = 0.02; AC: 74.4%, p = 0.008). Conclusion: RDC technique has the potential to improve image quality and ability to differentiate malignant from benign prostatic areas on DWIs of suspected prostatic cancer patients.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据