4.6 Article

The R-wave amplitude in V1 on baseline electrocardiogram correlates with the occurrence of high-degree atrioventricular block following left bundle branch block after transcatheter aortic valve replacement

期刊

EUROPACE
卷 -, 期 -, 页码 -

出版社

OXFORD UNIV PRESS
DOI: 10.1093/europace/euad066

关键词

Transcatheter aortic valve replacement; Left bundle branch block; Atrioventricular block; Permanent pacemaker implantation

向作者/读者索取更多资源

This study aimed to assess the association between the baseline R-wave amplitude in V1 ECG lead and the risk of developing high-degree AVB following new LBBB after TAVR in patients with normal QRS duration. The retrospective study included 117 patients, of whom 14 developed high-degree AVB requiring PPI (Group 1) and 103 did not (Group 2). There were no significant differences in baseline characteristics or procedural parameters between the two groups, but the R-wave amplitude in V1 was smaller in Group 1 compared to Group 2.
Aims Several procedural and electrocardiogram (ECG) parameters have been associated with the occurrence of high-degree atrioventricular block (AVB) requiring permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR). We hereunder sought to assess if the baseline R-wave amplitude in V1 ECG lead of patients with normal QRS duration undergoing TAVR is associated with a higher patient's risk for developing high-degree AVB following left bundle branch block (LBBB). Methods and results In this retrospective single-centre study in 720 consecutive patients who underwent TAVR, 141 (19.6%) patients with normal QRS duration developed a new LBBB after TAVR. The 24 (17%) patients who underwent PPI for reasons other than high-degree AVB were excluded from further analysis. In the remaining 117 study patients, 14 (12%) developed high-degree AVB requiring PPI (Group 1) while the remaining 103 (88%) patients did not (Group 2). There were no significant differences in baseline demographic or procedural characteristics nor in PR interval, QRS duration, and QRS axis between these two groups. The incidence of left anterior hemiblock was higher in Group 1 (3 of 14, 21.4%) than that in Group 2 (9 of 103, 8.7%), but the difference was not statistically significant (P = 0.156). The R-wave amplitude in V1 was smaller in Group 1 than that in Group 2 (0.029 +/- 0.04 mV vs. 0.11 +/- 0.14 mV, P = 0.0316). In the receiver-operating characteristics analysis, the cutoff for R-wave amplitude pre-TAVR was 0.03 mV, area under the curve = 0.7219 (P = 0.0002). Conclusion The R-wave amplitude in lead V1 during baseline ECG in patients with normal QRS duration may predict the occurrence of high-degree AVB following new LBBB after TAVR.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据